phi_publications:literature

Technical literature, project reports and guides from the Passive House Institute

The following overview lists many specialist publications, project reports and guides from the Passive House Institute. Most of them are available for download as PDF files. Distribution or reproduction of the contents is permitted provided the complete source is cited. The keywords highlight the focus of the publications.

Sort by year and language (using the small arrows next to the column titles) or filter keywords to find relevant publications quickly and easily!

* Tip: Always use the singular (thermal bridge instead of thermal bridgeS)
* Tip: Try synonyms and generic terms (retrofit instead of refurbishment)
* Tip: Use British English spelling (user behaviOUr instead of user behavior; optimiSation instead of optimiZation)
* Tip: Scroll through the table to get an idea of the available keywords

Filter:

PublicationYearLanguageKey words
Passivhaus BuildTog Bremen-Findorff Energetische Untersuchung 2021DENew build, residential building, multi-storey housing / apartment building, monitoring, user behaviour, user experience, summer, passive cooling, heating energy consumption, pipe distribution losses, heating load, district heating, PHPP validation
BuildTog Darmstadt-Kranichstein: Monitoring (Endbericht) 2021DENew build, residential building, multi-storey housing / apartment building, monitoring, user behaviour, user experience, district heating, heating energy consumption, heating load
25 Jahre Passivhaus Darmstadt Kranichstein 2016DENew build, residential building, terraced house, monitoring, thermography, heating energy consumption, service life, component study, solar thermal energy, photovoltaics, gas heating, green roof / green façades, wastewater heat recovery, ground heat exchanger, electrical efficiency, thermally insulated sliding shutter, renewable energy, additional investment, PHPP validation, dynamic simulation, insulation, airtightness, thermal bridge, window, glazing, ventilation with heat recovery, radon
Durability of building fabric components and ventilation systems in passive houses 2019ENNew build, residential building, multi-storey housing / apartment building, terraced house, monitoring, thermography, heating energy consumption, service life, component study, green roof / green façades, electrical efficiency, PHPP validation, insulation, airtightness, thermal bridge, window, glazing, ventilation with heat recovery, radon, peer-reviewed, Darmstadt
Betriebsoptimierung Bahnstadt Heidelberg 2021DENew build, residential building, monitoring, building regulation, district, operational optimisation, heating load, heating energy consumption, DHW, district heating connection capacity, checklist
Messtechnische Bestimmung der Wärmeverlustkoeffizienten von Passivhaus-Wohngebäuden 2016DENew build, residential building, terraced house, single-family house, transmission loss, dynamic simulation, Dynbil, QUB test, co-heating test, climate chamber, hygrothermal simulation, monitoring, Austria, Darmstadt
CEPHEUS-Projektinformation Nr. 18: Klimaneutrale Passivhaus-Reihenhaussiedlung Hannover-Kronsberg 2001DENew build, residential building, monitoring, district, terraced house, heating energy consumption, ventilation with heat recovery, cost-effectiveness, additional investment, connection detail, roof, district heating, solar thermal energy, drying cabinet, electrical efficiency, airtightness, thermography, user guidance, user experience, Hannover
CEPHEUS-Projektinformation Nr. 19: Meßtechnische Untersuchung und Auswertung Klimaneutrale Passivhaus-Reihenhaussiedlung Hannover-Kronsberg 2001DENew build, residential building, monitoring, district, terraced house, energy demand, heating energy consumption, electricity consumption, heating load, building regulation, window ventilation, PHPP validation, district heating, pipe distribution losses, comparison low energy building, user guidance, Hannover
CEPHEUS-Projektinformation Nr. 20: Thermographische Untersuchung der Passivhaussiedlung Hannover-Kronsberg 2001DENew build, residential building, monitoring, district, terraced house, thermography, Hannover
CEPHEUS-Projektinformation Nr. 21: Vergleich von Messung und Simulation am Beispiel eines Passivhauses in Hannover-Kronsberg 2001DENew build, residential building, monitoring, district, terraced house, Dynbil, dynamic simulation, energy demand, heating energy consumption, ventilation with heat recovery, Hannover
Klimaneutrale Passivhaussiedlung Hannover-Kronsberg: Analyse im dritten Betriebsjahr (Endbericht) 2002DENew build, residential building, monitoring, district, terraced house, comfort, window ventilation, heating energy consumption, heating load, electricity consumption, ventilation with heat recovery, user behaviour, summer, shading, district heating, Hannover
Climate Neutral Passive House Estate in Hannover-Kronsberg: Construction and Measurement Result 2005ENNew build, residential building, monitoring, district, terraced house, energy demand, heating energy consumption, ventilation with heat recovery, cost-effectiveness, additional investment, connection detail, roof, district heating, solar thermal energy, electrical efficiency, airtightness, thermography, user guidance, comparison low energy building, summer, Hannover
Mehrgeschoss-Passivhaus Hamburg Pinnasberg 2005DENew build, residential building, monitoring, multi-storey housing / apartment building, underground car park, lift / elevator, gas heating, energy demand, heating energy consumption, heating load, pipe distribution losses, ventilation with heat recovery, primary energy, summer, shading, thermography, cellar access stairs, Hamburg
Ein nordorientiertes Passivhaus 2004DENew build, residential building, multi-storey housing / apartment building, homeowners' association, monitoring, north orientation, prefabrication, example project, energy demand, heating energy consumption, comfort, thermography, Frankfurt
Messtechnische Untersuchung und wissenschaftliche Auswertung zur saisonalen Wärmespeicherung über Sole-Register unter der Bodenplatte eines Passivhauses mit Dämmschürze (Abschlussbericht) 2010DENew build, residential building, single-family house, solid construction, monitoring, geothermal energy, operational optimisation, plinth insulation, floor slab, heat pump, ground storage, solar thermal energy
Are the energy savings of the passive house standard reliable? A review of the as-built thermal and space heating performance of passive house dwellings from 1990 to 20182020ENNew build, residential building, monitoring, energy demand, heating energy consumption, PHPP validation, example building, peer-reviewed
Monitoring Passivhäuser China: Bürogebäude und Arbeiterwohnheim in ZhuoZhou, Hebei, China 2019DENew build, residential building, non-residential building, residence hall, office building, monitoring, user experience, operational optimisation, energy demand, heating energy consumption, ventilation with heat recovery, active cooling, passive cooling, shading, dehumidification, heat pump China
Passivhaus-Konzept für Hallenbäder: Datenauswertung und Empfehlungen] 2018DENew build, non-residential building, monitoring, indoor swimming pool, ventilation with heat recovery, district heating, CHP plant, heating energy consumption, electricity consumption, airtightness, thermography, guide, pool water treatment, humidity, commissioning, THM measurement, water savings, wastewater heat recovery, checklist, cost-effectiveness, evaporation, energy management, energy demand, Lünen, Bamberg
Passivhaus-Konzept für Hallenbäder: Kurzleitfaden 2018DENew build, non-residential building, indoor swimming pool, guide, cost-effectiveness, integral planning, building services, energy demand
Passive House concept for indoor swimming pools: guidelines, Passivhaus-Konzept für Hallenbäder: Leitfaden (DE), Concept Passivhaus pour les piscines: Lignes directrices (FR) 2018EN, DE, FRNew build, non-residential building, indoor swimming pool, guide, cost-effectiveness, integral planning, building services, energy demand
Monitoring Passivhaus-Hallenbad Lippe-Bad Lünen 2013DENew build, non-residential building, monitoring, indoor swimming pool, pool water treatment, filter backwash water, fundamentals, energy demand, heating energy consumption, CHP plant, district heating, renewable energy, photovoltaics, electricity consumption, ventilation with heat recovery, airtightness, multi-zone PHPP, humidity, air quality, Lünen
Passivhaus-Hallenbad Bambados Monitoring 2015DENew build, non-residential building, monitoring, indoor swimming pool, multi-zone PHPP, operational optimisation, heating energy consumption, electricity consumption, DHW, CHP plant, photovoltaics, ventilation with heat recovery, lighting, heat pump, pool water treatment, airtightness, thermography, humidity, dehumidification, comfort, air quality, Bamberg
Verwaltungsgebäude der Polizei in Passivhaus-Qualität 2017DENew build, non-residential building , monitoring, office building, police station, garage, prefabrication, thermography, heating energy consumption, heat pump, ground heat exchanger, geothermal energy, passive cooling, shading, active cooling, concrete core tempering, ventilation with heat recovery, operational optimisation, energy demand, PHPP validation, electricity consumption, internal rainwater downpipe, internal sewage pipe, comfort, air quality
Passivhausschule Frankfurt Riedberg: Messtechnische Untersuchung und Analyse 2007DENew build, non-residential building, monitoring, school, kindergarten / nursery, sports hall, building regulation, wood pellet boiler, additional investment, cost-effectiveness, plinth insulation, floor slab, simulation, user guidance, passive cooling, shading, night ventilation, summer, ventilation with heat recovery, electricity consumption, heating energy consumption, PHPP validation, heating load, photovoltaics, lighting, comparison building standards, comfort, air quality, window ventilation, failure of the ventilation system, user experience, vestibule, Frankfurt
Langzeiterfahrung zur Funktion der Dämmschürze beim Projekt Passivhaus Grundschule Frankfurt-Riedberg 2011DENew build, non-residential building, monitoring, school, kindergarten / nursery, plinth insulation, floor slab, measurement, simulation, Frankfurt
Wissenschaftliche Begleitung, Qualitätssicherung und Messdatenauswertung beim Projekt "Fabrik als Passivhaus" (Endbericht) 2003DENew build, non-residential building, monitoring, factory, heating energy consumption, ventilation with heat recovery, ground heat exchanger, operational optimisation, loading bay, comparison building standards, dynamic simulation, airtightness, electricity consumption, summer
Leitfaden für energieeffiziente Bildungsgebäude 2010DENew build, retrofit, non-residential building, school, kindergarten / nursery, sports hall, air quality, guide, ventilation with heat recovery, air flow, internal heat gain, orientation, insulation, curtain wall / non-load bearing façade, airtightness, thermal bridge, cellar access stairs, floor slab, kitchen, heating demand, pipe distribution losses, radiator, summer, night ventilation, glazing, shading, passive cooling, lighting, window
Messdatenauswertung zu einem mit Passivhauskomponenten sanierten Mehrfamilienhaus und Anwendung eines validierten Gebäudesimulationsverfahrens zur Identifikation des Einflusses von Gebäudehülle, Haustechnik und Nutzung 2023DERetrofit, residential building, year of construction 1950s, EnerPHit, multi-storey housing / apartment building, solid construction, monitoring, user behaviour, loggia, balcony, photovoltaics, dynamic simulation, Dynbil, roof, district heating, cellar, ventilation with heat recovery, thermography, air quality, heating load, electricity consumption, window ventilation, energy demand, heating energy consumption, PHPP validation, user experience, parameter study, Gießen
Retrofit with Passive House components2022ENRetrofit, residential building, non-residential building, EnerPHit, fundamentals, comfort, energy demand, cost-effectiveness, peer-reviewed
Comparison of measured and calculated energy demand and assessment of the results - Innsbruck, Vergleich gemessener und berechneter Energiebedarfswerte und Bewertung der Ergebnisse - Innsbruck (DE) 2021EN, DERetrofit, residential building, non-residential building, EnerPHit, district, multi-storey housing / apartment building, school, energy demand, heating energy consumption, BEST sheet, energy performance certificate, monitoring, PHPP validation, comparison ProCasaClima, Innsbruck
Altbaumodernisierung mit Passivhaus-Komponenten 2009DERetrofit, residential building, EnerPHit, guide, listed building, insulation, airtightness, wooden beam, cellar access stairs, thermal bridge, window, roof, ventilation with heat recovery, DHW, pipe distribution losses, comfort, air quality, sound insulation, cost-effectiveness
Gebäudesanierung "Passivhaus im Bestand" in Ludwigshafen / Mundenheim: Messung und Beurteilung der energetischen Sanierungserfolge 2008DERetrofit, residential building, year of construction 1960s, multi-storey housing / apartment building, comparison low energy building, comparison KfW40, monitoring, loggia, airtightness, thermography, heating energy consumption, heating load, summer, electricity consumption, window ventilation, air quality, ventilation with heat recovery, thermography, comfort, summer, humidity, Ludwigshafen
Sanierung mit Passivhauskomponenten: Untersuchungen zu den Bestandsgebäuden Tevesstraße Frankfurt a.M. 2009DERetrofit, residential building, year of construction 1950s, complete retrofit, multi-storey housing / apartment building, window, thermal bridge, airtightness, thermography, Frankfurt
Sanierung mit Passivhauskomponenten: Planungsbegleitende Beratung und Qualitätssicherung Tevesstraße Frankfurt a.M. 2009DERetrofit, residential building, year of construction 1950s, complete retrofit, multi-storey housing / apartment building, comparison building standards, airtightness, cellar ceiling, vertical extension, prefabrication, rainwater downpipe, window, balcony, thermography, thermal bridge, compact heat pump, solar thermal energy, ventilation with heat recovery, pipe distribution losses, cost-effectiveness, monitoring, Frankfurt
Sanierung mit Passivhauskomponenten: Messtechnische Untersuchung und Auswertung Tevesstraße Frankfurt a.M. 2009DERetrofit, residential building, year of construction 1950s, complete retrofit, multi-storey housing / apartment building, heating energy consumption, gas heating, heating load, DHW, electricity consumption, primary energy, compact heat pump, summer, ventilation with heat recovery, PHPP validation, radiator, solar thermal energy, monitoring, Frankfurt
Monitoring Altbausanierung zum Passivhaus: Verbrauch - Raumluftqualität - Kellerfeuchte (Tevesstraße Frankfurt a.M.) 2011DERetrofit, residential building, year of construction 1950s, multi-storey housing / apartment building, humidity, air quality, airtightness, dynamic simulation, ventilation with heat recovery, user behaviour, window ventilation, comparison building standards, monitoring, Frankfurt
Jean-Paul-Platz 4 in Nürnberg: Energetische Gebäudesanierung mit Faktor 10 (Abschlussbericht der wissenschaftlichen Begleitforschung 2005DERetrofit, residential building, year of construction 1930s, complete retrofit, multi-storey housing / apartment building, insulation, window, thermal bridge, airtightness, wooden beam, air quality, thermography, ventilation with heat recovery, gas heating, energy demand, heating energy consumption, heating load, cost-effectiveness, comparison building standards, humidity, comfort, summer, solar thermal energy, DHW, user behaviour, Nuremberg
Ökonomische Evaluierung zweier Sanierungsprojekte mit Dokumentation der abgerechneten Kosten: Hoheloogstraße und Schlesierstraße in Ludwigshafe 2010DERetrofit, residential building, year of construction 1960s, complete retrofit, multi-storey housing / apartment building, cost-effectiveness, additional investment, comparison low energy building, life cycle costs, Ludwigshafen
Energetische Sanierung eines denkmalgeschützten Speichergebäudes mit aufgesprühter Zellulose-Innendämmung: Bauphysikalische Begleitmessung 2010DERetrofit, residential building, year of construction 1910s, residence hall, interior insulation, cellulose, wooden beam, humidity, window, listed building, monitoring, Wartin
Untersuchung zum Außenluftwechsel und zur Luftqualität in sanierten Wohnungen mit konventioneller Fensterlüftung und mit kontrollierter Lüftung 2010DERetrofit, residential building, year of construction 1960s, multi-storey housing / apartment building, ventilation with heat recovery, window ventilation, user behaviour, air quality, heating energy consumption, comparison low energy building, monitoring, Ludwigshafen
Wissenschaftliche Analyse eines auf vorgefertigten Vakuum-Paneel-Verbundplatten beruhenden Innendämmsystems (Abschlussbericht) 2011DEComponent study, laboratory test, retrofit, residential building, year of construction 1960s, multi-storey housing / apartment building, residence hall, interior vacuum insulation, humidity, hygrothermal simulation, listed building, monitoring, Neuwied
Sanierung der Hohenzollern-Höfe: Monitoring & Simulation des Feuchtegehalts in Wandaufbau und Holzbalkenköpfen für vier verschiedene Innendämmsysteme 2015DERetrofit, residential building, year of construction 1920s, multi-storey housing / apartment building, listed building, interior insulation, wooden beam, humidity, airtightness, ventilation with heat recovery, thermography, hygrothermal simulation, monitoring, Ludwigshafen
Step by Step: retrofits with Passive House components 2016ENRetrofit, residential building, non-residential building, EnerPHit, step-by-step retrofit, retrofit plan, guide, monitoring, airtightness, comfort, insulation, roof, listed building, interior insulation, window, cellar ceiling, balcony, ventilation with heat recovery, energy supply, cooling, dehumidification, solar thermal energy, photovoltaics, cost-effectiveness
Wärmeversorgungskonzepte in Niedrigenergie- und Passivhäusern im ökonomischen Vergleich 2017DENew build, retrofit, residential building, non-residential building, energy supply, heat pump, gas heating, oil heating, wood pellet boiler, CO2 compensation, ventilation with heat recovery, wastewater heat recovery, solar thermal energy, cost-effectiveness, comparison low energy building
Energie-, CO2- und Kosteneinsparungen durch die Verwendung von Kunststoffenstern mit unterschiedlicher Verglasung im Vergleich zum einfach verglasten Aluminiumfenster im Klima Neu Delhi, Indien (Kurzstudie des Passivhaus Instituts im Auftrag von ALUPLAST INDIA) 2016 DE Component study, window, glazing, aluminium, plastic, cost-effectiveness, hot climate, India
smartwin compact: Economic optimum in the regions of Europe (On behalf of pro passivhausfenster GmbH, Oberaudorf, Germany) 2014 EN Component study, window, wood-aluminium, glazing, cost-effectiveness
Evaluation of social housing building types in Mexico: Study of energy efficiency, additional costs and CO2 mitigation as a basis for the preparation of the "Supported NAMA for Sustainable Housing in Mexico - Mitigation Actions and Financing Packages" presented at COP17 in Durban 2012ENNew build, residential building, social housing, single-family house, terraced house, multi-storey housing / apartment building, cost-effectiveness, comparison building standards, hot climate, temperate climate, Mexico
Wirtschaftlichkeit von Wärmedämm-Maßnahmen im Gebäudebestand 2005 2005DERetrofit, residential building, non-residential building, insulation, additional investment, interior insulation, roof, cellar ceiling, pipe distribution losses, cost-effectiveness, life cycle costs
Bewertung energetischer Anforderungen im Lichte steigender Energiepreise für die EnEV und die KfW-Förderung] 2008DENew build, retrofit, residential building, non-residential building, primary energy, cost-effectiveness, additional investment, life cycle costs, comparison Effizienzhaus, DIN V 18599, parameter study
Energie und CO2-Einsparungen durch die Verwendung von blaugelb Triotherm+ im Vergleich zu Montagewinkeln aus Stahl und zum Fenstereinbau bündig mit der Außenwand (Kurzstudie des Passivhaus Instituts im Auftrag von Meesenburg Großhandel KG) 2019 DEComponent study, window, mounting bracket, installation detailing, thermal bridge, comfort
Hochwärmedämmende Fenstersysteme: Untersuchung und Optimierung im eingebauten Zustand 2003DEComponent study, window, spacer, installation detailing, double casement window, thermal bridge, comfort
Heizlast in Passivhäusern - Validierung durch Messungen 2005DENew build, retrofit, residential building, heating load, dynamic simulation, Dynbil, monitoring, PHPP validation
Luftdichtheitsmessung von Multifunktionsbändern (MFB) 2016DEComponent study, laboratory test, multifunctional tape, airtightness, installation gap
Zur Dauerhaftigkeit von Luftdichtheitskonzepten bei Passivhäusern - Feldmessungen (Endbericht) 2005DEAirtightness, monitoring
Energetische Bewertung von Wohnungslüftungsgeräten mit Feuchterückgewinnung 2008DEHumidity recovery, component study, ventilation with heat recovery, comfort, hygrothermal simulation, Dynbil, energy demand
Untersuchung von Dunstabzugssystemen in Wohnküchen 2022DEComponent study, recirculating extractor hood, exhaust air extractor hood, heating demand, odour reduction, laboratory test, motorised damper
Luftwechselraten in bewohnten, sehr luftdichten Gebäuden mit kontrollierter Wohnungslüftung / Monitoring in einem Passivhaus-Geschosswohnbau (Endbericht) 2005DENew build, retrofit, residential building, window ventilation, user behaviour, ventilation with heat recovery, heating energy consumption, electricity consumption, air quality, comfort, humidity, monitoring
Integrale Planung für die Realisierung eines öffentlichen Hallenbades mit Konzepten der Passivhaustechnologie (Endbericht) 2011DENew build, retrofit, non-residential building, indoor swimming pool, pool water treatment, energy demand, primary energy, humidity, ventilation with heat recovery, water savings, cost-effectiveness, dynamic simulation, Lünen
Grundlagenuntersuchung der bauphysikalischen und technischen Bedingungen zur Umsetzung des Passivhauskonzepts im öffentlichen Hallenbad 2009DENew build, retrofit, non-residential building, indoor swimming pool, pool water treatment, humidity recovery, comfort, summer, energy demand, dynamic simulation, guide
Einfluss von Kellerdeckendämmung auf die Feuchtebelastung von Kellerräumen 2009DERetrofit, residential building, non-residential building, cellar ceiling, insulation, humidity, hygrothermal simulation
Dynamisches Verhalten und Wärmeübergabeverluste von Flächenheizungen 2005DENew build, retrofit, residential building, non-residential building, surface heating, radiator, user behaviour, dynamic simulation, energy demand, comfort
Begleitung von Planung und Bau eines ausgewählten Projekts: Energieeffizientes Einfamilienhaus in Königsfeld (Endbericht) 2005DENew build, residential building, solid construction, orientation, Königsfeld
Energetische Auswirkungen thermisch getrennter Balkonanschlüsse im Vergleich zu ungetrennten Balkonanschlüssen in unterschiedlichen Klimaten (Studie des Passivhaus Instituts im Auftrag von Schöck, Baden-Baden, Deutschland) 2017DEComponent study, balcony connection, energy demand, thermal bridge
Energieeffizienz 2001DEFundamentals, heating energy consumption, electricity consumption
Optimum glazing in the regions of Europe considering the embedded energy (On behalf of Compagnie de Saint-Gobain, Generaldelegation Mitteleuropa and Swisspacer Vetrotech Saint-Gobain (International) AG) 2014ENComponent study, glazing, embodied energy
Untersuchung von Strohballen und Strohballenkonstruktionen hinsichtlich ihrer Anwendung für ein energiesparendes Bauen unter Berücksichtigung der lasttragenden Bauweise 2008DEstraw bale, primary energy, cost-effectiveness
Energy monitoring of residential buildings in the Passive House city district of Heidelberg-Bahnstadt, Energie-Monitoring von Wohngebäuden im Passivhaus-Stadtteil Heidelberg-Bahnstadt (DE) 2016EN, DENew build, residential building, district, residence hall, heating energy consumption, electricity consumption, district heating, underground car park, pipe distribution losses, PHPP validation, monitoring, Heidelberg
Energy efficiency of the Passive House Standard: Expectations confirmed by measurements in practice, Die Energieeffizienz des Passivhaus-Standards: Messungen bestätigen die Erwartungen in der Praxis (DE) 2015EN, DENew build, retrofit, residential building, district, semi-detached house, multi-storey housing / apartment building, heating energy consumption, airtightness, PHPP validation, monitoring, Wiesbaden, Hannover, Stuttgart, Frankfurt, Heidelberg, Innsbruck, Frankfurt, Ludwigshafen, Vienna, Nuremberg
Passive House Quality Police Administrative Building (short version) 2017ENNew build, non-residential building, office building, police station, solid construction, prefabrication, heat pump
Handbook for energy-efficient educational-use buildings Leitfaden für energieeffiziente Bildungsgebäude (DE)2010EN, DENew build, non-residential building, school, kindergarten / nursery, sports hall, air quality, summer, energy demand, guide
Windows in a step-by-step retrofit, Fenster in einer schrittweise durchgeführten Sanierung (DE) 2015EN, DEComponent study, retrofit, step-by-step retrofit, window, installation detailing, glazing, shading, insulation, guide
Integrating wood beams into the airtight layer, Einbindung von Holzbalken in die luftdichte Ebene (DE) 2014EN, DEComponent study, laboratory test, retrofit, listed building, interior insulation, wooden beam, airtightness
Checklist for planning Passive House indoor swimming pools, Hallenbäder Checkliste Energiemanagement (DE) 2018EN, DENew build, retrofit, non-residential building, indoor swimming pool, checklist, guide, energy management, heating energy consumption, operational optimisation, pool water treatment, lighting, DHW, ventilation with heat recovery
Energy, CO2 and cost savings by using highly energy-efficient plastic spacer bars in comparison to aluminium and stainless steel spacer bars in different climates (Study by the Passivhaus Institut on behalf of SWISSPACER, Kreuzlingen, Switzerland), Energie-, CO2- und Kosteneinsparungen durch die Verwendung von höchst energieeffizienten Kunststoff-Abstandhaltern im Vergleich zu Aluminium- und Edelstahl-Abstandhaltern in unterschiedlichen Klimaten (Studie des Passivhaus Instituts im Auftrag von SWISSPACER, Kreuzlingen, Schweiz) (DE) 2017EN, DEComponent study, spacer, energy demand, cost-effectiveness
Validierung der Algorithmen für die thermische Gebäudesimulation an Hand von Feld-Messergebnissen 2023DEEnergy demand, renewable energy, Dynbil, dynamic simulation, parameter study, user behaviour
Implementation of the Passive House concept in Hospitals, Umsetzung des Passivhaus-Konzepts in Krankenhäusern (DE)2013EN, DENew build, non-residential building, hospital / clinic, fundamentals, energy demand, electricity consumption, lighting, DHW, water savings, pipe distribution losses, comfort, ventilation with heat recovery, cooling, airtightness, radiator, concrete core tempering, Frankfurt
Passivhäuser erfolgreich planen und bauen - Ein Leitfaden zur Qualitätssicherung 2004DENew build, residential building, non-residential building, guide, checklist, airtightness, thermal bridge, insulation, ventilation with heat recovery, window, shading, heating load, energy demand, solid construction, timber construction, user instruction
Optimisation of the PHPP for old buildings with high energy consumption 2015ENRetrofit, residential building, PHPP validation, cooling, summer, heating load, energy demand, dynamic simulation, Dynbil
Ventilation concepts for energy retrofits / Lüftungskonzepte für die Sanierung 2016EN, DERetrofit, residential building, multi-storey housing / apartment building, step-by-step retrofit, ventilation with heat recovery, year of construction 1960s
Rahmenkonzept: Hochsommerliche Kühlung in der Bahnstadt2025DENew build, residential building, multi-storey housing / apartment building, guide, active cooling, summer, compact heat pump, Heidelberg

phi_publications/literature.txt · Last modified: by dvoelp