planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package:phpp_-_validated_and_proven_in_practice

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package:phpp_-_validated_and_proven_in_practice [2020/08/04 14:07] – [Comparison with measured data] wfeistplanning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package:phpp_-_validated_and_proven_in_practice [2020/08/04 14:18] – [Comparison with measured data] wfeist
Line 12: Line 12:
 \\ \\
 |{{ :picopen: comp_PHPP_measurements.png }}| |{{ :picopen: comp_PHPP_measurements.png }}|
-|//**Figure 1: \\ Comparison of measured consumption (statistical data) with the PHPP calculation.** \\ \\ It is only possible to compare average measured results from sufficiently large statistical samples \\ because individual consumption values fluctuate too much on account of the different user behaviours. \\ The average values match the PHPP results almost exactly.//|+|//**Figure 1: \\ Comparison of measured consumption (statistical data) with the PHPP calculation.** \\ \\ It is only possible to compare average measured results from sufficiently large statistical samples because individual consumption values fluctuate too much on account of the different user behaviours. The average values match the PHPP results almost exactly.//|
 \\ \\
 It is surprising that the results of the average measured values agree so well with the PHPP calculation. This is probably coincidental, because neither the accuracy of the measurement nor of the calculation is very high. Nevertheless, the depicted values are actual measured data - and the calculated results are those which were computed before the start of construction and already published before completion of the buildings. \\ It is surprising that the results of the average measured values agree so well with the PHPP calculation. This is probably coincidental, because neither the accuracy of the measurement nor of the calculation is very high. Nevertheless, the depicted values are actual measured data - and the calculated results are those which were computed before the start of construction and already published before completion of the buildings. \\
 +\\
 +We often get the question, why there is such a huge [[operation:operation_and_experience:measurement_results:energy_use_measurement_results#summary|fluctuation of the energy demand between different users]]: This is actually the case for all energy standards and not specific for energy efficient buildings - and it does not matter much in the case of passive houses, because even the highest consumption is still very small.\\
 \\ \\
 ===== More accurate than conventional methods ===== ===== More accurate than conventional methods =====
planning/calculating_energy_efficiency/phpp_-_the_passive_house_planning_package/phpp_-_validated_and_proven_in_practice.txt · Last modified: 2024/05/15 15:40 by yaling.hsiao@passiv.de