planning:refurbishment_with_passive_house_components:thermal_envelope:floor_replacement_svartbaecksvaegen [2017/12/13 18:05] – [Floor Replacement: Svartbäcksvägen] kdreimaneplanning:refurbishment_with_passive_house_components:thermal_envelope:floor_replacement_svartbaecksvaegen [2017/12/13 18:05] – [Floor Replacement: Svartbäcksvägen] kdreimane
Line 12: Line 12:
  
 One of the main challenges when fitting a new ground floor to an existing building is to reduce thermal bridging to an acceptable minimum. This helps to avoid heat loss and condensation (which in turn may damage the building structure and/or cause mould growth).  One of the main challenges when fitting a new ground floor to an existing building is to reduce thermal bridging to an acceptable minimum. This helps to avoid heat loss and condensation (which in turn may damage the building structure and/or cause mould growth). 
-{{:picopen:thermal_grapics.png?550|}}+[{{:picopen:thermal_grapics.png?550|}}]
  
 On the outside, the earth is dug out, new drainage pipes are positioned and the trench is filled with FOAMGLAS® gravel. Insulation boards with draining properties are fitted to the wall. The resulting Ψ–value of the wall/floor connection for the PHPP input is approximately 0.020-0.040W/(mK) –depending on the actual moisture content of the FOAMGLAS® pebbles. On the outside, the earth is dug out, new drainage pipes are positioned and the trench is filled with FOAMGLAS® gravel. Insulation boards with draining properties are fitted to the wall. The resulting Ψ–value of the wall/floor connection for the PHPP input is approximately 0.020-0.040W/(mK) –depending on the actual moisture content of the FOAMGLAS® pebbles.
planning/refurbishment_with_passive_house_components/thermal_envelope/floor_replacement_svartbaecksvaegen.txt · Last modified: 2017/12/13 18:05 by kdreimane