planning:building_services:ventilation:facade_integration_of_ventilation_units

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
planning:building_services:ventilation:facade_integration_of_ventilation_units [2024/10/24 15:03] – [Heat recovery in Core hole] yaling.hsiao@passiv.deplanning:building_services:ventilation:facade_integration_of_ventilation_units [2024/10/30 10:47] (current) – [See also] yaling.hsiao@passiv.de
Line 1: Line 1:
 ====== Façade Integration of Ventilation Units for Deep Renovation ====== ====== Façade Integration of Ventilation Units for Deep Renovation ======
 +
 +Author: Rainer Pfluger
  
 ===== Facade Integration of Ventilation Unis – Options, Pros and Cons ===== ===== Facade Integration of Ventilation Unis – Options, Pros and Cons =====
Line 47: Line 49:
 [{{ :picopen:ventilation_04.png?600 |Figure 3: Prototype of three heat exchangers combined with the “golden ratio” of the width of the large rectangle to the width of the small rectangle in a tube (45° inclination)}}] [{{ :picopen:ventilation_04.png?600 |Figure 3: Prototype of three heat exchangers combined with the “golden ratio” of the width of the large rectangle to the width of the small rectangle in a tube (45° inclination)}}]
  
 +For economic reasons, the square version might be the best option, as only one heat exchanger is necessary in this case. However – depending on the necessary flow rate – the heat exchanger and consequently the  diameter of the core hole can become quite large. Whether core hole drilling of the respective diameter is permissible for static reasons must be checked on a case-by-case basis.
 +
 +===== Summary =====
 +Within the outPHit project, several options for façade integrated ventilation systems were investigated and demonstrated by various prototypes. A checklist and a tool will help for planning and quality assurance.
 +When planning a renovation, the first thing to decide is where the device can be installed as easily as possible. In addition, the question of whether the outdoor- and exhaust air ducts should be routed outside or inside must be clarified. According to this, the device position next to the window is to be preferred in the context of a complete renovation with ETICS and window replacement, and installation can be simplified and accelerated with the help of prefabricated installation frames. The option of a heat exchanger in the core hole, on the other hand, remains a solution if the ventilation is to be installed after the renovation of the building envelope.
 +
 +===== References =====
 +**[outPHit WPx ] **Rainer Pfluger: Multifunctional window element in serial renovation, Innsbruck, 2024 \\
 +**[outPHit D4.6]** Rainer Pfluger: Façade Integration of Devices, 2024 as part of Steiger, J.: outPHit D4.6 Deep Renovation Guidelines, 2024.\\
 +**[outPHit Tool D4.6]** Pfluger, R., Hammes, S.: Devices in the insulation layer, calculation Tool, v1.0, 2024.\\
 +
 +
 +----
 +
 +
 +{{:picopen:outphit_logo_description.png?400}}{{:picopen:eu_logo_description.png?400}}
 +
 +
 +
 +----
 +
 +===== See also =====
 +
 +[[planning:refurbishment_with_passive_house_components]]
 +
 +[[planning:building_services:ventilation]]
 +
 +[[https://passipedia.org/eu_projects_publications#outphit_-_deep_retrofits_made_faster_cheaper_and_more_reliable|outPHit - Deep retrofits made faster, cheaper and more reliable]]
planning/building_services/ventilation/facade_integration_of_ventilation_units.1729774994.txt.gz · Last modified: by yaling.hsiao@passiv.de