examples:residential_buildings:multi-family_buildings:central_europe:the_world_s_first_passive_house_darmstadt-kranichstein_germany

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
examples:residential_buildings:multi-family_buildings:central_europe:the_world_s_first_passive_house_darmstadt-kranichstein_germany [2019/02/21 11:49] cblagojevicexamples:residential_buildings:multi-family_buildings:central_europe:the_world_s_first_passive_house_darmstadt-kranichstein_germany [2020/08/17 10:17] – [Literature] wfeist
Line 61: Line 61:
 |   **Exterior\\ wall**   | Fabric reinforced mineral render;\\ 275 mm of expanded polystyrene insulation (EPS) (installed in two layers at that time, 150+125 mm);\\ 175 mm sand-lime brick masonry;\\ 15 mm continuous interior gypsum plastering; wood-chip wallpaper, emulsion paint coating |{{:picopen:wdvs_daemmung_passivhaus_mit_logo.jpg?150}}|  0.14  | |   **Exterior\\ wall**   | Fabric reinforced mineral render;\\ 275 mm of expanded polystyrene insulation (EPS) (installed in two layers at that time, 150+125 mm);\\ 175 mm sand-lime brick masonry;\\ 15 mm continuous interior gypsum plastering; wood-chip wallpaper, emulsion paint coating |{{:picopen:wdvs_daemmung_passivhaus_mit_logo.jpg?150}}|  0.14  |
 |   **Basement\\ ceiling**   | Surface finish on fibreglass fabric;\\ 250 mm polystyrene insulation boards;\\ 160 mm concrete;\\ 40 mm polystyrene acoustic insulation;\\ 50 mm cement floor finish;\\ 8-15 mm of parquet, adhesive;\\ sealing solvent-free |{{:picopen:keller_daemmung_mit_logo.jpg?150}}|  0.13  | |   **Basement\\ ceiling**   | Surface finish on fibreglass fabric;\\ 250 mm polystyrene insulation boards;\\ 160 mm concrete;\\ 40 mm polystyrene acoustic insulation;\\ 50 mm cement floor finish;\\ 8-15 mm of parquet, adhesive;\\ sealing solvent-free |{{:picopen:keller_daemmung_mit_logo.jpg?150}}|  0.13  |
-|  **Windows** | Triple-pane low-e glazing with Krypton filling: U<sub>g</sub>-value 0.7 W/(m²K).\\ Wooden window with polyurethane foam insulated framework\\ (CO2-foamed, HCFC free, handcrafted)|{{:picopen:fenster_mit_logo.jpg?150}}|  0.7  |+|  **Windows**  | Triple-pane low-e glazing with Krypton filling: U<sub>g</sub>-value 0.7 W/(m²K).\\ Wooden window with polyurethane foam insulated framework\\ (CO2-foamed, HCFC free, handcrafted)|{{:picopen:fenster_mit_logo.jpg?150}}|  0.7  |
 |   **Heat\\ recovery\\ ventilation**   | Counterflow air-to-air heat exchanger;\\ Located in the cellar (approx.  9°C in the winter),\\ carefully sealed and thermally insulated,\\ the first one to use electronically commutated DC fans.|{{:picopen:waermetauscher_mit_logo.jpg?150}}|  heat recovery\\ rate approx. 80%  |\\ |   **Heat\\ recovery\\ ventilation**   | Counterflow air-to-air heat exchanger;\\ Located in the cellar (approx.  9°C in the winter),\\ carefully sealed and thermally insulated,\\ the first one to use electronically commutated DC fans.|{{:picopen:waermetauscher_mit_logo.jpg?150}}|  heat recovery\\ rate approx. 80%  |\\
 \\ \\
Line 236: Line 236:
 \\ \\
 **[Feist 1997b]** Wolfgang Feist: "Der Härtetest: Passivhäuser im strengen Winter 1996/97"; GRE-Inform, 12/1997.\\ **[Feist 1997b]** Wolfgang Feist: "Der Härtetest: Passivhäuser im strengen Winter 1996/97"; GRE-Inform, 12/1997.\\
-(**"The Endurance Test: Passive Houses in the harsh winter of 1996/97"**; GRE-Inform, 12/1997)\\+(**"The Endurance Test: Passive Houses in the harsh winter of 1996/97"**; GRE-Inform, 12/1997) (available online: 
 +[[https://www.researchgate.net/publication/343675507_Der_Hartetest_Passivhauser_im_strengen_Winter_199697|Endurance test Passive House]])\\
 \\ \\
 **[Feist 1997c]** Wolfgang Feist: "Passivhaus Darmstadt-Kranichstein - Planung, Bau, Ergebnisse", Fachinformation PHI 1997/4, 1. Auflage, 16 Seiten.\\ **[Feist 1997c]** Wolfgang Feist: "Passivhaus Darmstadt-Kranichstein - Planung, Bau, Ergebnisse", Fachinformation PHI 1997/4, 1. Auflage, 16 Seiten.\\
examples/residential_buildings/multi-family_buildings/central_europe/the_world_s_first_passive_house_darmstadt-kranichstein_germany.txt · Last modified: 2024/02/08 10:41 by yaling.hsiao@passiv.de