planning:refurbishment_with_passive_house_components:building_integrated_photovoltaics_bipv_in_step_by_step_retrofitting_projects [2016/01/05 17:17] – created kdreimane | planning:refurbishment_with_passive_house_components:building_integrated_photovoltaics_bipv_in_step_by_step_retrofitting_projects [2016/03/10 17:44] – kdreimane | ||
---|---|---|---|
Line 45: | Line 45: | ||
* Another key factor to consider when choosing the right glazing is the negative impact of ultraviolet (UV) radiation into the interiors, on furnishings, | * Another key factor to consider when choosing the right glazing is the negative impact of ultraviolet (UV) radiation into the interiors, on furnishings, | ||
- | {{ : | + | {{ : |
* ListenpunktThe semi-transparent a-Si photovoltaic glazing systems provides a complete flexibility in transparency without compromising the capability of the natural sun light diffusing into the interior spaces. Depending on the transparency degree, the light transmission can vary from 10 to 30%, which is normally the optimal range for interior space. | * ListenpunktThe semi-transparent a-Si photovoltaic glazing systems provides a complete flexibility in transparency without compromising the capability of the natural sun light diffusing into the interior spaces. Depending on the transparency degree, the light transmission can vary from 10 to 30%, which is normally the optimal range for interior space. | ||
- | * Double or triple glazing photovoltaic insulating units can also be incorporated into the project providing improved thermal insulation properties, reaching Uvalues of 0,7W/m2K. The following table shows some properties of the most common glazing configurations. | + | * Double or triple glazing photovoltaic insulating units can also be incorporated into the project providing improved thermal insulation properties, reaching Uvalues of 0,7W/m< |
\\ | \\ | ||
Line 67: | Line 67: | ||
+ | |//The sole responsibility for the content of Passipedia lies with the authors. \\ | ||
+ | While certain marked articles have been created with the support of the EU, they do not necessarily reflect the opinion of the European Union; \\ | ||
+ | Neither the EACI nor the European Commission are responsible for any use that may be made of the information contained therein.//| \\ |