Previous revision
planning:calculating_energy_efficiency [2019/02/21 10:07] cblagojevicplanning:calculating_energy_efficiency [2020/08/05 12:48] (current) – [Precise model: dynamic simulation] wfeist
Line 15: Line 15:
 As the comparison of the simulation and measurement results shows, such a model can provide accurate results ([AkkP 5] (see Figure 1), but this requires a lot of effort and in addition, not all required data are of equal importance. Even so, inappropriate values for "unimportant" data can lead to incorrect results.  \\ As the comparison of the simulation and measurement results shows, such a model can provide accurate results ([AkkP 5] (see Figure 1), but this requires a lot of effort and in addition, not all required data are of equal importance. Even so, inappropriate values for "unimportant" data can lead to incorrect results.  \\
 \\ \\
-|{{ :picopen:simulation_dynbil_mit_logo.png }}| +|{{ :picopen:meassim_wall.png }}| 
-|//**Figure 1: \\ Comparison between measurement and simulation results in \\ the Darmstadt Kranichstein Passive House project.**\\ \\ Simulation programme used: DYNBIL; see [[planning:calculating energy efficiency:Dynamic simulation]]; \\ Published in [AkkP 5]//|\\+|//**Figure 1: \\ Comparison between measurement and simulation results in the Darmstadt Kranichstein Passive House project. Note that there are deviations - mainly due to limited resources in the accuracy and number of sensors used during the monitoring. (longwave radiation could only be measured on the horizontal plane)**\\ \\ Simulation programme used: DYNBIL; see [[planning:calculating energy efficiency:Dynamic simulation]]; \\ Published in [AkkP 5]//|\\
 \\ \\
  
Line 84: Line 84:
  
 [[planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package:calculations in hot and humid climates|PHPP calculations in hot and humid climates]] \\ [[planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package:calculations in hot and humid climates|PHPP calculations in hot and humid climates]] \\
 +
 +[[:a_simplified_method_for_determining_thermal_comfort_in_summer_for_buildings_without_active_cooling|PHPP assessment of thermal comfort during summer in buildings without active cooling]]
 +\\
 \\ \\
  