planning:building_services:ventilation:differentiation_between_vv_and_vn50_values [2023/01/30 11:38] – [Calculation methodology] zbastianplanning:building_services:ventilation:differentiation_between_vv_and_vn50_values [2025/07/30 15:23] (current) – [Single family house - Calculation of TFA, VV and Vn50] yaling.hsiao@passiv.de
Line 25: Line 25:
 ===== Vn50 – Net air volume for pressurisation test ===== ===== Vn50 – Net air volume for pressurisation test =====
  
-The air volume V<sub>n50</sub> within the heated building envelope is the volume that will be used for calculating [[planning:airtight_construction:general_principles:blower_door_test|the n50 air leakage value]]. It is supposed to indicate the //actual// volume of air that will be heated or cooled within the building and should be calculated separately for each room. The calculation should be carried out in accordance with detailed rules given in the [[https://passivehouse.com/downloads/03_building_criteria_en.pdf| Criteria for Buildings]], section 3.2.10 Airtightness of the building envelope.  +The air volume V<sub>n50</sub> within the heated building envelope is the volume that will be used for calculating [[planning:airtight_construction:general_principles:blower_door_test|the n50 air leakage value]]. It is supposed to indicate the //actual// volume of air that will be heated or cooled within the building and should be calculated separately for each room. The calculation must be carried out in accordance with detailed rules given in the [[https://passivehouse.com/downloads/03_building_criteria_en.pdf| Criteria for Buildings]], section 3.2.10 Airtightness of the building envelope.  
  
  
Line 53: Line 53:
 [[planning:airtight_construction:airtightness_measurements_in_passive_houses|Airtightness measurements in Passive Houses]] {{:picopen:members_only.png?nolink&20|}} [[planning:airtight_construction:airtightness_measurements_in_passive_houses|Airtightness measurements in Passive Houses]] {{:picopen:members_only.png?nolink&20|}}
  
-[[planning:refurbishment_with_passive_house_components:thermal_envelope:airtightness|Airtightness - how and why?]] +[[planning:airtight_construction:airtightness_and_airtightness_measurement|Airtightness - how and why?]] 
  
  
  