planning:building_services:ventilation:differentiation_between_vv_and_vn50_values [2019/02/27 09:19] cblagojevicplanning:building_services:ventilation:differentiation_between_vv_and_vn50_values [2019/10/24 09:09] – [Calculation methodology] cblagojevic
Line 43: Line 43:
 Therefore, the base floor area of the stairwell is simply multiplied by the clear height of the storey. The volume for flights of stairs and intermediate landings does not have to be subtracted. Therefore, the base floor area of the stairwell is simply multiplied by the clear height of the storey. The volume for flights of stairs and intermediate landings does not have to be subtracted.
  
 +The volume of elevator shafts and any other kind of shafts inside the thermal envelope are part of the air volume and is fully taken into account. The volume of  the elevator, pipes etc. themselves (building component) is not taken into account, therefore it is not deducted. The base area of the shaft can thus be multiplied with the clear height of the storey.
  
  
Line 72: Line 73:
  
 [[planning:refurbishment_with_passive_house_components:thermal_envelope:airtightness|Airtightness - how and why?]]  [[planning:refurbishment_with_passive_house_components:thermal_envelope:airtightness|Airtightness - how and why?]] 
- 
- 
----- 
-{{:picopen:sinfonia_logo_cmyk_hr.jpg?nolink&160 |}} 
-//SINFONIA stands for “**S**mart **IN**itiative of cities **F**ully c**O**mmited to i**N**vest in **A**dvanced large-scaled energy solutions”. This project has received funding from the European Union’s Seventh Programme for research, technological development and demonstration under grant agreement No 609019.// 
- 
- 
- 
-\\ 
-{{:picopen:azeb.jpg?nolink&80 |}}  
-//AZEB stands for “Affordable Zero Energy Buildings”. This project has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 754174.//  
- 
  
  
  
-\\ 
-{{:picopen:euroflagge.jpg?nolink&100 |}}  
-//This sole responsibility for the content of this publication lies with the authors. It does not necessarily reflect the opinion of the European Commission are responsible for any use that may be made of the information contained therein.// 
planning/building_services/ventilation/differentiation_between_vv_and_vn50_values.txt · Last modified: 2023/01/30 11:52 by zbastian