planning:building_services:ventilation:comparison_of_energy_performance_of_ventilation_systems_using_passive_vs_active_heat_recovery

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Last revisionBoth sides next revision
planning:building_services:ventilation:comparison_of_energy_performance_of_ventilation_systems_using_passive_vs_active_heat_recovery [2020/08/10 08:12] – [Representation of active heat recovery systems in the PHPP] alangplanning:building_services:ventilation:comparison_of_energy_performance_of_ventilation_systems_using_passive_vs_active_heat_recovery [2020/08/17 10:32] alang
Line 47: Line 47:
 Figure 1 also shows that the additional electricity demand of a heat pump solution for heat recovery is typically on the order of 10 kWh/(m² yr), a value that is much higher than the total electricity consumption for heating in a Passive House with a heat pump system. Figure 1 also shows that the additional electricity demand of a heat pump solution for heat recovery is typically on the order of 10 kWh/(m² yr), a value that is much higher than the total electricity consumption for heating in a Passive House with a heat pump system.
  
-[{{  :picopen:vent_article_tmikeska_figure_1.png  |**Figure 1: Comparison of final energy use of different investigated systems (including frost protection and energy for fans)**}}]+[{{  :picopen:vent_article_tmikeska_figure_1.png?800  |**Figure 1: Comparison of final energy use of different investigated systems (including frost protection and energy for fans)**}}]
  
  
-[{{  :picopen:vent_article_tmikeska_figure_2.png  |**Figure 2: Comparison of final energy use of different investigated systems shown in %**}}]+[{{  :picopen:vent_article_tmikeska_figure_2.png?800  |**Figure 2: Comparison of final energy use of different investigated systems shown in %**}}]
  
 =====Representation of active heat recovery systems in the PHPP===== =====Representation of active heat recovery systems in the PHPP=====
planning/building_services/ventilation/comparison_of_energy_performance_of_ventilation_systems_using_passive_vs_active_heat_recovery.txt · Last modified: 2023/04/28 17:22 by jgrovesmith