planning:building_services:ventilation:basics:types_of_ventilation [2022/03/24 14:40] yaling.hsiao@passiv.deplanning:building_services:ventilation:basics:types_of_ventilation [2022/05/22 19:20] – [The convenient solution: supply and exhaust air systems with heat recovery] wfeist
Line 117: Line 117:
  
 Ventilation can also take place if a simple exhaust air system and external air inlets are used.  The external air inlets let fresh (cold) air in the required amounts into the rooms.  However, for the Passive House the ventilation heat losses that would be caused by the disposal of the unused extract air would be much too high.  It would only be possible to adjust the energy balance with a high heating output. Ventilation can also take place if a simple exhaust air system and external air inlets are used.  The external air inlets let fresh (cold) air in the required amounts into the rooms.  However, for the Passive House the ventilation heat losses that would be caused by the disposal of the unused extract air would be much too high.  It would only be possible to adjust the energy balance with a high heating output.
 +
 +===== Heat Recovery with a Counterflow Heat Exchanger =====
  
 **In Central Europe, Passive Houses only work if a highly efficient heat recovery system is also present**  This recovers the heat from the exhaust air and using a heat exchanger, transfers it back into the supply air without mixing the air flows. Today, modern ventilation technology allows a heat recovery rate of  between 75 and 95 %. This is possible due to counterflow heat exchangers and special energy-efficient fans (with so-called EC motors with a particularly high effectiveness), so that the recovered heat is 8 to 15 times the electricity consumed.\\ **In Central Europe, Passive Houses only work if a highly efficient heat recovery system is also present**  This recovers the heat from the exhaust air and using a heat exchanger, transfers it back into the supply air without mixing the air flows. Today, modern ventilation technology allows a heat recovery rate of  between 75 and 95 %. This is possible due to counterflow heat exchangers and special energy-efficient fans (with so-called EC motors with a particularly high effectiveness), so that the recovered heat is 8 to 15 times the electricity consumed.\\