certification:certified_passive_houses
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
certification:certified_passive_houses [2019/10/28 08:56] – [Building Certification] cblagojevic | certification:certified_passive_houses [2025/03/19 16:47] (current) – [Also see] gergina.radeva@passiv.de | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== Building Certification ====== | ====== Building Certification ====== | ||
- | In the [[http://www.passivhausprojekte.de/projekte.php?lang=en|Passive House project database]], certified Passive Houses are marked with the PHI logo. | + | Building **certification provides quality assurance** and brings many **[[https://passivehouse.com/03_certification/ |
- | Current certification criteria | + | |
- | **[[certification:building_criteria_2015| Building | + | The [[.:building_certificaton_guide|Building |
- | [[http:// | + | Passive Houses are not introduced by law or regulation - they are a voluntarily agreed standard. However, this standard is clearly and unambiguously defined: The Passive House Institute has formulated the criteria for Passive Houses for different building tasks (e.g. residential buildings, office- educational buildings). These are exclusively so-called " |
- | [[certification: | + | ---- |
- | [[certification: | + | ====== Energy Standards ====== |
+ | ==== Passive House Classic, Plus and Premium ==== | ||
- | [[certification:certified_passive_houses:example documents|Examples of documents that need to be submitted for certification]] | + | {{: |
- | \\ \\ | + | [[:basics:what_is_a_passive_house|Passive House buildings]] are characterised by especially high levels of indoor comfort with minimum energy consumption. The Passive House Standard offers excellent economic efficiency especially for new builds. |
- | ===== Thermal conductivity - Passive House certification procedure ===== | + | |
- | As per the certification criteria for the certification of Passive Houses, documents verifying the thermal conductivity (lambda value) of each insulation material and building component must be submitted. For Passive | + | The [[.: |
- | \\ \\ | + | |
- | ===== Supplementary provisions to the criteria ===== | + | |
- | [[Certification of terraced houses according to Passive House Institute criteria]] | + | |
- | [[Certification of buildings in which the ground floor is used for commercial purposes]] | + | ---- |
- | [[Evaluation | + | ==== EnerPHit Classic, Plus and Premium ==== |
+ | |||
+ | {{: | ||
+ | |||
+ | The EnerPHit **Classes Classic, Plus or Premium** can be achieved depending on the use of renewable energy sources | ||
+ | |||
+ | Step-by-step retrofits can also achieve EnerPHit standard with the help of an [[https:// | ||
+ | |||
+ | ---- | ||
+ | |||
+ | ==== Low Energy Building ==== | ||
+ | |||
+ | {{: | ||
+ | |||
+ | ---- | ||
+ | |||
+ | ====== Criteria for Buildings ====== | ||
+ | |||
+ | The official Building Criteria can be downloaded from the Passive House Institute' | ||
+ | |||
+ | Older versions of the building criteria can be found in the [[https:// | ||
+ | |||
+ | [[.: | ||
+ | |||
+ | Translations into other languages exist and are produced by various partners and Passive House organisations worldwide. Please note that translations of criteria are purely informative and not binding: [[.: | ||
+ | |||
+ | **Supplementary provisions to the criteria** | ||
+ | |||
+ | With version 10 of the building criteria, the following supplementary provisions were integrated into the [[https:// | ||
+ | |||
+ | [[.: | ||
+ | |||
+ | [[.: | ||
+ | |||
+ | ---- | ||
+ | |||
+ | ====== Building Certification Guide ====== | ||
+ | |||
+ | ===== valid with " | ||
+ | |||
+ | In addition to general information on certification, | ||
+ | |||
+ | As of version 10c of the [[https:// | ||
+ | |||
+ | [[.: | ||
+ | |||
+ | [[.: | ||
+ | |||
+ | ---- | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | |||
+ | |||
+ | ====== Certified Buildings worldwide ====== | ||
+ | |||
+ | The first Passive House was built in 1991. Since then, the principle has proven itself thousands of times over, and long-term experience proves its functionality. Passive House Buildings can be realized worldwide and in all climate zones. The [[https:// | ||
---- | ---- | ||
Line 30: | Line 82: | ||
===== Also see ===== | ===== Also see ===== | ||
- | [[certification: | + | [[: |
+ | |||
+ | [[.: | ||
+ | |||
+ | [[.: | ||
- | [[certification:enerphit]] | + | [[:basics: |
- | {{ :picopen: | + | [[.:addendum_concerning_the_use_of_vacuum_insulation|]] |
- | [[http:// | + | [[.:evaluation_of_server_and_server_room_efficiency_for_non-residential_buildings_that_exceed_the_primary_energy_criterion|]] |
+ | [[: | ||
certification/certified_passive_houses.1572249364.txt.gz · Last modified: by cblagojevic