User Tools

Site Tools


certification:certified_passive_houses

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
certification:certified_passive_houses [2024/04/18 23:18] – [Passive House Classic, Plus and Premium] jgrovesmithcertification:certified_passive_houses [2025/03/19 16:47] (current) – [Also see] gergina.radeva@passiv.de
Line 1: Line 1:
 ====== Building Certification ====== ====== Building Certification ======
  
-Building **certification provides quality assurance** and brings many **[[https://passivehouse.com/03_certification/02_certification_buildings/01_benefits-of-certification/01_benefits-of-certification.htm|advantages]]** for all parties involved. The focus is on planning, because only practice-oriented planning can be translated into a functioning building at the construction site: Airtightness, thermal bridge free design, high-quality windows and installation, ventilation system and other building services must be designed in a targeted manner and coordinated with each other (in the professional world, this is referred to as integral planning). In this context, it is advisable to contact an [[education_training:building_certifier|accredited Building Certifier]] at an early stage of planning. At this stage, problems identified by the certifier can still be easily remedied. +Building **certification provides quality assurance** and brings many **[[https://passivehouse.com/03_certification/02_certification_buildings/01_benefits-of-certification/01_benefits-of-certification.htm|advantages]]** for all parties involved. The focus is on planning, because only practice-oriented planning can be translated into a functioning building at the construction site: Airtightness, thermal bridge free design, high-quality windows and installation, ventilation system and other building services must be designed in a targeted manner and coordinated with each other (in the professional world, this is referred to as integral planning). In this context, it is advisable to contact an [[:education_training:building_certifier|accredited Building Certifier]] at an early stage of planning. At this stage, problems identified by the certifier can still be easily remedied.
  
-The [[certification:building_certificaton_guide|Building Certification Guide]] provides a clear summary of general information on certification (e.g. benefits, process, first steps). As of version 10c of the [[https://passivehouse.com/downloads/03_building_criteria_en.pdf| Criteria for Buildings]] PHI has integrated the content of the Building Certification Guide into the Criteria for Buildings document. PHI has discontinued the development of the Building Certification Guide as a separate document.+The [[.:building_certificaton_guide|Building Certification Guide]] provides a clear summary of general information on certification (e.g. benefits, process, first steps). As of version 10c of the [[https://passivehouse.com/downloads/03_building_criteria_en.pdf| Criteria for Buildings]] PHI has integrated the content of the Building Certification Guide into the Criteria for Buildings document. PHI has discontinued the development of the Building Certification Guide as a separate document.
  
- +Passive Houses are not introduced by law or regulation - they are a voluntarily agreed standard. However, this standard is clearly and unambiguously defined: The Passive House Institute has formulated the criteria for Passive Houses for different building tasks (e.g. residential buildings, office- educational buildings). These are exclusively so-called "functional criteria", i.e. individual structural or technical details are not prescribed, but an overall coherent planning with a competently executed energy balance, elaboration of the details and documentation of the components is required. This ensures that the designed building can really produce the results expected of it in practice. The [[:operation:operation_and_experience:measurement_results|measurement]] results of a large number of examined Passive House projects confirm this.
-Passive Houses are not introduced by law or regulation - they are a voluntarily agreed standard. However, this standard is clearly and unambiguously defined: The Passive House Institute has formulated the criteria for Passive Houses for different building tasks (e.g. residential buildings, office- educational buildings). These are exclusively so-called "functional criteria", i.e. individual structural or technical details are not prescribed, but an overall coherent planning with a competently executed energy balance, elaboration of the details and documentation of the components is required. This ensures that the designed building can really produce the results expected of it in practice. The [[operation:operation_and_experience:measurement_results|measurement]] results of a large number of examined Passive House projects confirm this.+
  
 ---- ----
- 
  
 ====== Energy Standards ====== ====== Energy Standards ======
  
-====Passive House Classic, Plus and Premium====+==== Passive House Classic, Plus and Premium ====
  
-{{:picopen:siegel_zertifiziertes_ph_classic_en.jpg?150 |}}\\ [[basics:what_is_a_passive_house|Passive House buildings]] are characterised by especially high levels of indoor comfort with minimum energy consumption.  The Passive House Standard offers excellent economic efficiency especially for new builds.+{{:picopen:siegel_zertifiziertes_ph_classic_en.jpg?150  }}\\ 
 +[[:basics:what_is_a_passive_house|Passive House buildings]] are characterised by especially high levels of indoor comfort with minimum energy consumption. The Passive House Standard offers excellent economic efficiency especially for new builds.
  
-The [[certification:passive_house_categories|Passive House Classes]]  **Classic, Plus or Premium** can be achieved depending on the use of renewable energy sources. +The [[.:passive_house_categories|Passive House Classes]] **Classic, Plus or Premium** can be achieved depending on the use of renewable energy sources.
- +
-\\ +
-------+
  
 +----
  
-==== EnerPHit Classic, Plus and Premium====+==== EnerPHit Classic, Plus and Premium ====
  
-{{:picopen:siegel_enerphit_classic_en.jpg?150 |}} +{{:picopen:siegel_enerphit_classic_en.jpg?150  }}[[:planning:refurbishment_with_passive_house_components|EnerPHit]] is the established Standard for refurbishment of existing buildings using Passive House components. Despite the slightly higher energy demand, it offers virtually all the advantages of the Passive House Standard.
-[[planning:refurbishment_with_passive_house_components|EnerPHit]] is the established Standard for refurbishment of existing buildings using Passive House components. Despite the slightly higher energy demand, it offers virtually all the advantages of the Passive House Standard.+
  
 The EnerPHit **Classes Classic, Plus or Premium** can be achieved depending on the use of renewable energy sources The EnerPHit **Classes Classic, Plus or Premium** can be achieved depending on the use of renewable energy sources
  
-Step-by-step retrofits can also achieve EnerPHit standard with the help of an [[https://passivehouse.com/03_certification/02_certification_buildings/06_process/06_process.html|EnerPHit Retrofit Plan]] and [[https://passivehouse.com/03_certification/02_certification_buildings/06_process/06_process.html|pre-certification]]** as an EnerPHit (or a Passive House) project. +Step-by-step retrofits can also achieve EnerPHit standard with the help of an [[https://passivehouse.com/03_certification/02_certification_buildings/06_process/06_process.html|EnerPHit Retrofit Plan]] and [[https://passivehouse.com/03_certification/02_certification_buildings/06_process/06_process.html|pre-certification]]** as an EnerPHit (or a Passive House) project. **
-**+
  
-------+----
  
 ==== Low Energy Building ==== ==== Low Energy Building ====
  
-{{:picopen:siegel_low_energy_building.jpg?150 |}} The PHI Low Energy Building Standard is suitable for buildings which do not fully comply with Passive House criteria for various reasons. +{{:picopen:siegel_low_energy_building.jpg?150  }}The PHI Low Energy Building Standard is suitable for buildings which cannot attain the criteria for Passive House Classic for various reasons, but still offer many of its advantages.
  
 +----
  
-------+====== Criteria for Buildings ======
  
 +The official Building Criteria can be downloaded from the Passive House Institute's website: [[https://passivehouse.com/03_certification/02_certification_buildings/08_energy_standards/08_energy_standards.html|Criteria for the Passive House, EnerPHit and PHI Low Energy Building Standard]]. They are published in German, English (in SI and IP units) and Spanish.
  
 +Older versions of the building criteria can be found in the [[https://passivehouse.com/03_certification/02_certification_buildings/08_energy_standards/08_certification_criteria_archive.html|archive]].
  
-====== Building Criteria ====== +[[.:building_criteria_2015|Changes to the Building Criteria]] are described in the respective criteria document.
-The official Building Criteria are published by the Passive House Institute in [[https://passiv.de/de/03_zertifizierung/02_zertifizierung_gebaeude/04_enerphit/04_enerphit.htm|German]], [[https://passivehouse.com/03_certification/02_certification_buildings/08_energy_standards/08_energy_standards.html|English]] and [[https://passipedia.org/_media/picopen/9f_160815_phi_criterios_edificios_es.pdf | Spanish]]. They can be downloaded from the Passive House Institute's website: [[https://passiv.de/downloads/03_building_criteria_en.pdf|Criteria for the Passive House, EnerPHit and PHI Low Energy Building Standard]]  The Building Criteria are also available in [[https://passivehouse.com/downloads/03_building_criteria_ip_en.pdf|IP units]]: +
  
-Older versions of the building criteria can be found in the [[https://passivehouse.com/03_certification/02_certification_buildings/08_energy_standards/08_certification_criteria_archive.html|archive]].  +Translations into other languages exist and are produced by various partners and Passive House organisations worldwide. Please note that translations of criteria are purely informative and not binding: [[.:certified_passive_houses:certification_criteria_in_other_languages|Building Criteria in other languages]].If you would also like to translate criteria into your national language, please contact the Passive House Institute. You will then receive translation instructions.
- +
-[[certification:building_criteria_2015|Changes to the Building Criteria]] are described in the respective criteria document.  +
- +
-Translations into other languages exist and are produced by various partners and Passive House organisations worldwide. If you would also like to translate criteria into your national language, please contact the Passive House Institute. You will then receive translation instructions. Please note that translations of criteria are purely informative and not binding: [[certification:certified_passive_houses:certification_criteria_in_other_languages|Building Criteria in other languages]].+
  
 **Supplementary provisions to the criteria** **Supplementary provisions to the criteria**
  
-With version 10 of the building criteria, the following supplementary provisions were integrated into the [[https://passiv.de/downloads/03_building_criteria_en.pdf| Building Criteria document]]:+With version 10 of the building criteria, the following supplementary provisions were integrated into the [[https://passiv.de/downloads/03_building_criteria_en.pdf|Building Criteria document]]:
  
-[[Certification of terraced houses according to Passive House Institute criteria]]+[[.:certification_of_terraced_houses_according_to_passive_house_institute_criteria|]]
  
-[[Certification of buildings in which the ground floor is used for commercial purposes]]+[[.:certification_of_buildings_in_which_the_ground_floor_is_used_for_commercial_purposes|]]
  
 ---- ----
Line 75: Line 68:
 [[.:certified_passive_houses:example_documents|Sample documents that need to be submitted for certification]] [[.:certified_passive_houses:example_documents|Sample documents that need to be submitted for certification]]
  
 +----
  
 +{{ :picopen:passivhaus-zertifizierungen_kontinenten_en_01.2025.jpg?nolink&375|Development of Passive House certifications (January 2024). Current figures and other graphs can be found [[https://passivehouse-international.org/index.php}}
  
-[{{:picopen:passivhaus-zertifizierungen_en_jan2023.jpg?nolink&375|Development of Passive House certifications (January 2023). Current figures and other graphs can be found [[https://passivehouse-international.org/index.php}}]]] 
  
  
 ====== Certified Buildings worldwide ====== ====== Certified Buildings worldwide ======
-The first Passive House was built in 1991. Since then, the principle has proven itself thousands of times over, and long-term experience proves its functionality. Passive House Buildings can be realized worldwide and in all climate zones. The [[https://passivehouse.com/03_certification/02_certification_buildings/02_certification_buildings.htm|world map of certified buildings]] gives a good overview of certified buildings worldwide. The current figures and development can be found [[https://passivehouse-international.org/index.php?page_id=65|here]]. In the [[https://passivehouse-database.org/index.php?lang=en|Passive House Database]], you can filter for certified buildings. In addition, these are also marked with the PHI logo{{:picopen:ph_database.png?40}}.  
- 
  
 +The first Passive House was built in 1991. Since then, the principle has proven itself thousands of times over, and long-term experience proves its functionality. Passive House Buildings can be realized worldwide and in all climate zones. The [[https://passivehouse.com/03_certification/02_certification_buildings/02_certification_buildings.htm|world map of certified buildings]] gives a good overview of certified buildings worldwide. The current figures and development can be found [[https://passivehouse-international.org/index.php?page_id=65|here]]. In the [[https://passivehouse-database.org/index.php?lang=en|Passive House Database]], you can filter for certified buildings. In addition, these are also marked with the PHI logo{{:picopen:ph_database.png?40}}.
  
 ---- ----
  
 +===== Also see =====
 +
 +[[:examples|Built examples]]
 +
 +[[.:certified_passive_houses:certification_of_passive_house_offices|]]
 +
 +[[.:enerphit|]] 
  
 +[[:basics:passive_house_-_assuring_a_sustainable_energy_supply:project-specific_primary_energy_requirements_for_passive_house_certification|]]
  
 +[[.:addendum_concerning_the_use_of_vacuum_insulation|]] 
  
 +[[.:evaluation_of_server_and_server_room_efficiency_for_non-residential_buildings_that_exceed_the_primary_energy_criterion|]]
  
-===== Also see =====  +[[:planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package:calculation_guide_for_temperature_reduction_factors|]]
-[[:examples|Built examples]].  +
-[[.:certified_passive_houses:certification_of_passive_house_offices|]]  +
-[[.:enerphit|]] [[:basics:passive_house_-_assuring_a_sustainable_energy_supply:project-specific_primary_energy_requirements_for_passive_house_certification|]] [[.:addendum_concerning_the_use_of_vacuum_insulation|]] [[.:evaluation_of_server_and_server_room_efficiency_for_non-residential_buildings_that_exceed_the_primary_energy_criterion|]] [[:planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package:calculation_guide_for_temperature_reduction_factors|]]+
  
  
certification/certified_passive_houses.1713475099.txt.gz · Last modified: by jgrovesmith