planning [2014/09/18 18:19] – external edit 127.0.0.1planning [2023/08/10 12:02] (current) – [See also] yaling.hsiao@passiv.de
Line 1: Line 1:
-====== Planning ======+====== Planning and Construction ======
  
 +[{{ :picopen:energiebilanz_mit_logo.png?500|**Any Passive House project must be planned based on an** [[:planning:calculating_energy_efficiency:energy_balances_-_background|energy balance.]]\\
 +\\
 +The [[:planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package|Passive House Planning Package (PHPP)]] is an effective and user-friendly energy balancing tool allowing designers to plan and optimise Passive House buildings. It supports all details which need to be considered when planning a Passive House: [[:planning:thermal_protection:integrated_thermal_protection|insulation]], [[:planning:airtight_construction|airtightness]], [[:basics:building_physics_-_basics:what_defines_thermal_bridge_free_design|Thermal bridge free design ]], [[:planning:thermal_protection:windows|Passive House windows]], [[:planning:building_services:ventilation|ventilation]], heating loads, [[:planning:building_services:heating_and_dhw:heating|heating]], [[:basics:summer|summer comfort]], etc. }}]
  
-|{{ :picopen:energiebilanz_mit_logo.png }}|**Any Passive House project must be planned based on an** [[planning:calculating_energy_efficiency:energy_balances_-_background| energy balance.]] \\ \\ The [[planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package|Passive House Planning Package (PHPP)]] is an effective and user-friendly energy balancing tool allowing designers to plan and optimise Passive House buildings. It supports all details which need to be considered when planning a Passive House: [[planning:thermal_protection:integrated_thermal_protection|insulation]], [[planning:airtight_construction|airtightness]], [[basics:building_physics_-_basics:heat_transfer:thermal_bridges|thermal bridge free design]], [[planning:thermal_protection:windows|Passive House windows]], [[planning:building_services:ventilation|ventilation]], heating loads, [[planning:building_services:heating_and_dhw:heating|heating]], [[basics:summer|summer comfort]], etc. | +\\ 
-\\  +**This section contains information about the following topics:**
-This section contains information about the following topics:+
  
-  * [[planning:thermal_protection|Building envelope]]+   * [[:planning:thermal_protection|]] 
 +  * [[:planning:thermal_protection:windows|Passive House windows]] 
 +  * [[:basics:building_physics_-_basics:what_defines_thermal_bridge_free_design|Thermal bridge free design ]] 
 +  * [[:planning:calculating_energy_efficiency|Energy balance]]
  
 + \\ **When planning a Passive House, these components are important:**
  
 +  * [[:planning:thermal_protection:integrated_thermal_protection|]]
 +  * [[:planning:building_services|Building services]]
 +  * [[:planning:airtight_construction|]]
  
-  [[planning:thermal_protection:windows|Passive House windows]]+ \\ **The definition of the term "Passive House" and the requirements set up for Passive Houses and EnerPHit-refurbishments can be found here:**
  
 +  * [[:basics:what_is_a_passive_house|What is a Passive House]]
 +  * [[:basics:passive_house_checklist|Check list]] for planning and implementation of Passive Houses
 +  * [[http://www.passiv.de/en/03_certification/02_certification_buildings/02_certification_buildings.htm|Criteria]] for Passive Houses and EnerPHit-refurbishments
 +  * [[:planning:component_guidelines_for_cost-optimal_passive_houses_and_enerphit_retrofits|]]
  
 + \\ **The Passive House Institute provides several tools:**
  
-  * [[basics:building_physics_-_basics:heat_transfer:thermal_bridges|Thermal bridge free design]]+  * [[:planning:tools|]]
  
 + \\ **Information about Passive Houses using passive cooling techniques in summer can be found here (suitable for climates in which night temperatures keep being low (<18°C) even in hot periods; e.g. Central and Northern Europe):**
  
-  * [[planning:calculating_energy_efficiency|Energy balance]]+  * [[:basics:summer|]]
  
-\\ + \\ **Information about Passive Houses using active cooling techniques in hot or hot and humid climates (suitable for climates in which passive cooling can not guarantee to give comfortable indoor climate; e.g. if temperatures are above ~ 22°C all night or if there is high humidity:**
-When planning Passive House, all components are important: +
-  [[planning:thermal_protection:integrated_thermal_protection|Thermal insulation]] +
-  [[planning:building_services|Building services]] +
-  * [[planning:airtight_construction]]+
  
-\\ +  * [[:planning:calculating_energy_efficiency:phpp_-_the_passive_house_planning_package:calculations_in_hot_and_humid_climates|]]
-The definition of the term "Passive House" and the requirements set up for Passive Houses and EnerPHit-refurbishments can be found here: +
-  * [[basics:what_is_a_passive_house|]] +
-  * [[basics:Passive House checklist|Check list]] for planning and implementation of Passive Houses  +
-  * [[http://www.passiv.de/en/03_certification/02_certification_buildings/02_certification_buildings.htm|Criteria]] for Passive Houses and EnerPHit-refurbishments +
-  * [[planning:other attributs for passive houses]] +
-  * [[planning:Component guidelines for cost-optimal Passive Houses and EnerPHit retrofits]] +
-\\ +
-The Passive House Institute provides several tools: +
-  * [[planning:Tools|]] +
-\\+
  
-Information about Passive Houses in summer can be found here: + \\ **Through the refurbishing of buildings, significant energy savings can be made:** 
-  * [[basics:summer|]] + 
-\\ +  * [[:planning:refurbishment_with_passive_house_components|]] 
-Through the refurbishing of buildings, significant energy savings can be made: + 
-  * [[planning:refurbishment_with_passive_house_components]] + \\ **The number of non-residential and residential Passive Houses with special user-based requirements is increasing:** 
-\\ + 
-The number of non-residential Passive Houses with special user-based requirements is increasing: +  * [[:planning:non-residential_passive_house_buildings|]] 
-  * [[planning:non-residential_passive_house_buildings]] +  * [[:basics:passive_house_-_assuring_a_sustainable_energy_supply:renewable_primary_energy_demand_in_residential_buildings|]] 
-\\+ 
 + \\ **Information about planning Passive Houses in different climates:** 
 + 
 +  * [[:basics:passive_houses_in_different_climates|]] 
 + 
 +---- 
 + 
 +====== Quality Assurance ====== 
 + 
 +This section compiles the main tasks regarding quality assurance in the course of site supervision, up to the time of final approval. It must be ensured that all that has been arranged in the plans, especially the implementation plans, is also implemented on site. Generally recognised technical regulations and relevant provisions must be complied with in the process. For innovative projects in particular, requirements often go far beyond regulations as the technology used in such structures has often not yet been included in the standards. The special features of energy-efficient buildings are presented in the following sections in detail. Special attention is paid to practical relevance and the examples herein can thus serve as a basis for numerous approaches. It is essential, however, that an investigation of further local or national technical regulations be carried out by the designer. Designers should inform their clients comprehensively about the advantages and risks associated with innovative solutions and in return, clients should exempt designers from any liability extending beyond these risks. This should be done carefully in written form: it is advisable to include these aspects in the construction specifications that are signed by the client. 
 + 
 +Special aspects of quality assurance are presented in the following sections. 
 + 
 +  * [[:construction:quality_assurance:airtightness_and_wind_proofing|Airtightness and wind proofing]] {{:picopen:members_only.png?25}} 
 + 
 +  * [[:construction:quality_assurance:thermal_bridges|Thermal bridges]] {{:picopen:members_only.png?25}} 
 + 
 +  * [[:construction:quality_assurance:final_approval_and_initial_use|Final approval and initial use]] {{:picopen:members_only.png?25}} 
 + 
 +  * [[:construction:quality_assurance:nuremberg_case_study|]] 
 + 
 +===== See also ===== 
 + 
 +  * [[:planning:airtight_construction:general_principles:blower_door_test|Blowerdoor Test]] 
 +  * [[:construction:quality_assurance:nuremberg_case_study:examination_of_the_external_envelope_using_thermographic_imaging|Thermographic imaging]] 
 +  * [[:affiliate_literature:planning_and_building_a_passive_house|Affiliate Literature: Planning and Building a Passive House]]
  
-Information about planning Passive Houses in different climates: 
  
-  * [[basics:passive_houses_in_different_climates]] 
planning.1411057157.txt.gz · Last modified: 2015/10/29 09:14 (external edit)