planning:refurbishment_with_passive_house_components:thermal_envelope:airtightness [2019/02/07 11:40] cblagojevicplanning:refurbishment_with_passive_house_components:thermal_envelope:airtightness [2019/06/28 08:59] – [Penetrations of the airtight layer] cblagojevic
Line 113: Line 113:
 Besides the basic principles, the following guidelines are helpful for successful planning of the airtightness – whether for a new construction or for a refurbishment of an old building (based on [[planning:refurbishment_with_passive_house_components:thermal_envelope:airtightness:special_features_in_modernisations#Literature|[Feist 1995] ]]): Besides the basic principles, the following guidelines are helpful for successful planning of the airtightness – whether for a new construction or for a refurbishment of an old building (based on [[planning:refurbishment_with_passive_house_components:thermal_envelope:airtightness:special_features_in_modernisations#Literature|[Feist 1995] ]]):
   * **simplicity**: in order to prevent any deficiencies in the workmanship, all construction details should be as simple to carry out as possible   * **simplicity**: in order to prevent any deficiencies in the workmanship, all construction details should be as simple to carry out as possible
 +
   * preferably **large uniform** areas with a simple basic construction   * preferably **large uniform** areas with a simple basic construction
 +
   * selection of reliable and proven basic construction techniques – it is not necessary to develop completely new or exceptional sealing systems   * selection of reliable and proven basic construction techniques – it is not necessary to develop completely new or exceptional sealing systems
 +
   * **adherence to common principles** when planning different connections   * **adherence to common principles** when planning different connections
 +
   * in principle, any **penetrations** of the sealing envelope should be avoided or minimised\\   * in principle, any **penetrations** of the sealing envelope should be avoided or minimised\\
 \\ \\
Line 177: Line 181:
 Therefore, in new constructions as well as in modernisations, in practice particular attention must be paid to the following points for implementing an airtight building envelope: Therefore, in new constructions as well as in modernisations, in practice particular attention must be paid to the following points for implementing an airtight building envelope:
   * Preliminary planning   * Preliminary planning
 +
   * Coordination of the trades (order)   * Coordination of the trades (order)
 +
   * Time schedule   * Time schedule
 +
   * Monitoring of implementation\\   * Monitoring of implementation\\
 \\ \\
planning/refurbishment_with_passive_house_components/thermal_envelope/airtightness.txt · Last modified: 2022/02/15 19:37 by admin