planning:refurbishment_with_passive_house_components:prospects_for_the_modernisation_of_existing_buildings_using_highly_efficient_components [2011/10/26 10:22] – created anne.huse | planning:refurbishment_with_passive_house_components:prospects_for_the_modernisation_of_existing_buildings_using_highly_efficient_components [2018/11/05 09:55] (current) – cblagojevic | ||
---|---|---|---|
Line 1: | Line 1: | ||
+ | ====== Prospects for the modernisation of existing buildings using highly efficient components ====== | ||
+ | |||
+ | This article (based on a contribution to the 24th Session of the [[phi_publications: | ||
+ | |||
+ | ===== Read more ===== | ||
+ | |||
+ | |||
+ | [[planning: | ||
+ | |||
+ | [[planning: | ||
+ | |||
+ | [[planning: | ||
+ | |||
+ | [[planning: | ||
+ | |||
+ | [[planning: | ||
+ | |||
+ | [[planning: | ||
+ | |||
+ | |||
+ | ===== Summary ===== | ||
+ | |||
+ | Based on the examples dealt with in the 24th session of the Research Group for Cost-effective Passive Houses [AkkP 24], Passive House components are also suitable for the modernisation of existing buildings. Their application is both practicable and cost-effective. \\ | ||
+ | |||
+ | These measures \\ | ||
+ | • offer greater security against moisture-related damage, \\ | ||
+ | • improve thermal comfort due to higher surface temperatures \\ | ||
+ | • and double the potential for accessible energy savings. \\ | ||
+ | |||
+ | The attractiveness of a high quality standard of modernisation increases with the use of highly efficient components, as the quality of life of the occupants is improved perceptibly. | ||
+ | On the other hand, modernisation measures for existing buildings are an important means for stimulating the economy. Thus the measures discussed here represent one of the crucial areas in which economic growth can take place while at the same time relieving the environmental burden. | ||
+ | With the measures presented here, it is possible to achieve a considerable reduction in CO2 emissions. Improved efficiency in this sector means reduced consumption which enables an increase in the sensible use of renewable energy sources. | ||
+ | Other demonstration projects of the energy-efficient modernisation of buildings have been started recently. Avoiding the mistakes of the past by means of thermal bridge free design and effective home ventilation, | ||
+ | |||
+ | ===== Literature ===== | ||
+ | |||
+ | **[AkkP 24]** Einsatz von Passivhaustechnologien bei der Altbau-Modernisierung, | ||
+ | Refurbishment with Passive House components, Protocol Volume No. 23 of the Research Group for Cost-effective Passive Houses, Phase III; Passive House Institute; Darmstadt, 2003. \\ | ||
+ | |||
+ | |||
+ | **[AkkP 23]** Einfluss der Lüftungsstrategie auf die Schadstoff¬konzentration und –ausbreitung im Raum, Protokollband Nr. 23 des Arbeits¬kreises kosten¬günstige Passivhäuser Phase III; Passivhaus Institut; Darmstadt, 2003. | ||
+ | Influence of the ventilation strategy on the concentration and distribution of harmful substances in rooms, Protocol Volume No. 23 of the Research Group for Cost-effective Passive Houses Phase III; Passive House Institute; Darmstadt, 2003. \\ | ||
+ | |||
+ | **[Feist 1999]** Feist, | ||
+ | Feist, W.: Requirements for home ventilation in the Passive House, in: Research Group for Cost-effective Passive Houses, Protocol Volume No. 17, 1st edition, Darmstadt, 1999. \\ | ||
+ | |||
+ | **[Feist 2000]** Feist, | ||
+ | Feist, W.: Funding concept | ||
+ | |||
+ | **[Feist 2003]** Feist, | ||
+ | |||
+ | **[Hauser 2001]** Hauser, | ||
+ | Hauser, G. et al.: Thermal bridges in existing buildings, HEA-Research Group " | ||
+ | |||
+ | **[Michael 2001]** Michael, | ||
+ | Michael, K.; Eichhorn, S. et al.: Efficiency of ventilation systems in low-energy houses in North Rhine-Westfalia, | ||
+ | |||
+ | **[Peper 1999]** Peper, | ||
+ | Peper, S., Feist, W.: Airtight planning of Passive houses, CEPHEUS Project Information No. 7, Passive House Institute, Darmstadt, 1999; 4th edition 2002. \\ | ||
+ | |||
+ | **[Simons 2000]** Simons, | ||
+ | Simons, P.: Refurbishment of half-timbered construction using 12cm interior insulation; Measurement of moisture-related behaviour over a four-year period, Quadriga 1/2000, page 39ff. | ||
+ | |||
+ | |||