User Tools

Site Tools


planning:non-residential_passive_house_buildings

This is an old revision of the document!


Non-residential Passive House buildings

The Passive House Standard allows for extremely high levels of comfort as well as enormous energy savings - not only for residential buildings. The Passive House Standard has been successfully realised in many different types of buildings including offices, hostels, factories, administrative buildings, sports halls, schools and kindergartens.

Passive House schools

The Passive House Standard is a sensible alternative, not only for residential buildings. The Passive House Standard has been successfully realised in many different types of buildings including offices, hostels, factories, administrative buildings, sports halls and kindergartens.

Passive House school buildings are particularly interesting. Several school buildings have been realised using this standard and experiences gained from their use are now available: The Passive House Standards allows for energy savings of around 75% in comparison with average new school buildings - and of course there is no need for an additional heating or cooling system. The additional investment costs are within reasonable limits.

Passive House Schools - Boundary Conditions

Passive House schools – How to go about it

Air Quality in Schools

Best Practice Example - Riedberg Passive House School
The Passive House primary school and day nursery in Riedberg Frankfurt a.M. was opened in November 2004 after a construction period of only 14 months. The extra costs for achieving the Passive House Standard were a moderate 5.3 % in comparison with the currently valid EnEV (German energy saving regulations) standard. Read more
Secondary school in Baesweiler - modernised and energy-optimised to the Passive House Standard – a unique exemplary model!
Besides great environmental benefits like saving 90 % in heating costs and saving 530 tons of CO2 per year, the decision-makers of the City of Baesweiler made it their objective to contribute to the elimination of a misconception which also many architects subscribe to, that “Passive Houses are thickly insulated, disproportionate, impersonal blocks that are impossible to realise in a good quality architectural style”. Read more

Passive House office buildings

Certification of Passive House office buildings - Passive House office buildings are certified by the Passive House Institute (PHI) based on a standard occupancy level and corresponding internal gains of 3.5 W/m² (the reference area being the “treated floor area” of the PHPP, not the office area). From the PHI’s experience this value represents a typical average, taking into account an improved efficiency of the equipment used. The reasons why the PHI uses standard values for certification are partly to be able to ensure consistency and also because the use of a building is often not permanent and not always prior known. Read more


Passive House swimming pools

Passive House indoor swimming pool in Lünen
The indoor swimming pool in Lünen was built based on the Passive House approach established for this type of building in fundamental research by the Passive House Institute. In order to verify the effectiveness of the concept and approaches in the afore mentioned baseline study and to identify further potentials for optimisation, comprehensive monitoring of the pool was carried out during the first 1.5 years of operation.
Read more

Energy efficiency in public indoor swimming pools

The Passive house concept can be applied as a guiding principle for swimming pool buildings as well; the objective is to achieve optimal thermal comfort with significantly reduced energy consumption. The following article is a combination of different publications that deal with the basic principles of applying the Passive House concept for public indoor swimming pools.
Read more


Passive House concept in hospitals

Klinikum Frankfurt Höchst Rohbau Februar 2018 © Klinikum Frankfurt Höchst

Baseline study - implementing the Passive House concept in hospitals

This article is published in the Conference proceedings of the 18th International Passive House Conference 2014:

Evaluations of consumption statistics show that hospitals are among the buildings that consume the most energy. To evaluate and tap the conservation potential of retrofits and energy-efficient new builds, the State of Hesse studied basic issues for the implementation of the Passive House Standard in hospitals while constructing a new build for the Frankfurt Höchst Clinic. Read more

Download (pdf 5,8 MB) of the long version of the report “Baseline study on implementing the Passive House concept in hospitals” on www.passivehouse.com (only available in German language)

Aspects of efficient ventilation in hospitals

This article is published in the Conference proceedings of the 18th International Passive House Conference 2014:

Certain areas of hospitals require great air flows, with especially high air exchange rates found in operation rooms, labs, and areas where utensils are sterilized. Ventilation systems therefore make up a significant share of total energy demand. In addition, a large number of individual components are needed to filter and purify the air in compliance with hygienic and functional requirements for individual hospital areas (especially operating rooms). The sum of these individual pressure losses has a great impact on ventilators' power consumption. Read more


Energy efficiency in cafeterias and commercial kitchens

Passive House retail

REWE in Hanover/Wettbergen, ©PHI

These and more articles can be found in Protocol Volume No. 40 about “Passive House Retail Stores” of the “Research Group for Cost-effective Passive Houses” (only available in German).

Introduction: Retail stores as Passive Houses

Nr.40 Passive House retail establishments

Retrofitting non-residential buildings to the Passive House / EnerPHit-standard

Factors that influence the energy balance and affordability of non-residential EnerPHit-projects

Does it make sense to retrofit non-residential buildings with Passive House components if the buildings have a lot of internal heat sources?
Read more

Nr.48 Using Passive House technology for retrofitting non-residential buildings

See also

Nr.41 Cooling in non-residential Passive House buildings

planning/non-residential_passive_house_buildings.1623223780.txt.gz · Last modified: 2021/06/09 09:29 by nsukhija