User Tools

Site Tools


planning:guides_and_aids

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
planning:guides_and_aids [2026/02/20 16:26] egollwitzerplanning:guides_and_aids [2026/03/10 16:56] (current) yaling.hsiao@passiv.de
Line 10: Line 10:
 |[[:basics:building_physics_-_basics:thermal_bridges:timber_construction_thermal_bridge_catalogue|Timber construction thermal bridge catalogue ]]|In timber construction in particular, there are many elements that are located in the insulation level, such as wall end cross-sections or similar. In practice, it can happen for various reasons that details are not executed as planned and not as contained in this catalogue. If this is the case, the values from the thermal bridge catalogue can serve as an aid for estimating heat losses.|DE| |[[:basics:building_physics_-_basics:thermal_bridges:timber_construction_thermal_bridge_catalogue|Timber construction thermal bridge catalogue ]]|In timber construction in particular, there are many elements that are located in the insulation level, such as wall end cross-sections or similar. In practice, it can happen for various reasons that details are not executed as planned and not as contained in this catalogue. If this is the case, the values from the thermal bridge catalogue can serve as an aid for estimating heat losses.|DE|
 |[[:basics:building_physics_-_basics:thermal_bridges:thermal_bridges_catalogue|Thermal bridge catalogue for masonry and concrete walls]]|The catalogue contains typical Ψ-values and fRsi factors of common connection details in a building for masonry and concrete walls for a range of insulation thickness from 0 to 400mm, thereby allowing the estimation of Ψ-values for the use within various situations. A tool is also available for a more precise identification of the thermal bridge coefficients.|EN, DE| |[[:basics:building_physics_-_basics:thermal_bridges:thermal_bridges_catalogue|Thermal bridge catalogue for masonry and concrete walls]]|The catalogue contains typical Ψ-values and fRsi factors of common connection details in a building for masonry and concrete walls for a range of insulation thickness from 0 to 400mm, thereby allowing the estimation of Ψ-values for the use within various situations. A tool is also available for a more precise identification of the thermal bridge coefficients.|EN, DE|
-|Guide: calculation of thermal bridges (with ground) \\ [[:basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples:ewfs|]] \\  [[:basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples:iwfs|]] \\  [[:basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples:heatedb|]] \\  [[:basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples:unheatedb|]]|In practice, very different methods are often used for calculating thermal bridges of components in contact with the ground (thermal bridges towards the ground). All methods constitute an estimation ultimately; nevertheless, the procedure according to DIN EN ISO 10211 is recommended.|DE,EN|+|Guide: calculation of thermal bridges (with ground)|In practice, very different methods are often used for calculating thermal bridges of components in contact with the ground (thermal bridges towards the ground). All methods constitute an estimation ultimately; nevertheless, the procedure according to DIN EN ISO 10211 is recommended. \\ [[:basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples:ewfs|]] \\  [[:basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples:iwfs|]] \\  [[:basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples:heatedb|]] \\  [[:basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples:unheatedb|]]|DE,EN|
  
 ==== Thermal Bridge - Window ==== ==== Thermal Bridge - Window ====
planning/guides_and_aids.txt · Last modified: by yaling.hsiao@passiv.de