Last revisionBoth sides next revision
planning:airtight_construction:airtightness_measurements_in_passive_houses [2021/07/30 10:13] speperplanning:airtight_construction:airtightness_measurements_in_passive_houses [2021/08/24 11:11] nsukhija
Line 1: Line 1:
- 
-{{:picopen:members_area_picture.png?500}} 
-\\ 
- 
- 
 ====== Airtightness measurements in Passive Houses ====== ====== Airtightness measurements in Passive Houses ======
 ===== Instructions for carrying out measurements ===== ===== Instructions for carrying out measurements =====
Line 10: Line 5:
 Airtightness measurements in Passive House buildings are to be carried out uniformly worldwide according to ISO 9972, method 1. The deviations (these are not of a fundamental nature), clarifications and additions to the standard in relation to Passive Houses are described here. \\ Airtightness measurements in Passive House buildings are to be carried out uniformly worldwide according to ISO 9972, method 1. The deviations (these are not of a fundamental nature), clarifications and additions to the standard in relation to Passive Houses are described here. \\
 The calculation of the reference volume for passive houses is to be carried out according to the procedure listed below which is not part of the ISO 9972. The resulting volume is to be used for the determination of the n<sub>50</sub>-value. \\ The calculation of the reference volume for passive houses is to be carried out according to the procedure listed below which is not part of the ISO 9972. The resulting volume is to be used for the determination of the n<sub>50</sub>-value. \\
-For the calculation and documentation, it can be helpful to use the "room data sheets", which is included as an additional tool in PHPP Version 10.  \\+For the calculation and documentation, it can be helpful to use the "room data", which is included as an additional tool in PHPP Version 10.  \\
  
 ==== 1. Comparison of designations ==== ==== 1. Comparison of designations ====
Line 16: Line 11:
 The superseded standards EN 13829 and the current ISO 9972 use different designations in some places. For a better overview, the most important ones are compared here: The superseded standards EN 13829 and the current ISO 9972 use different designations in some places. For a better overview, the most important ones are compared here:
  
-[{{ :picprivate:000_bd_norm_bezeichnungen.jpg?400 |}}] +[{{ :picopen:000_bd_norm_bezeichnungen.jpg?400 |}}] 
  
 ==== 2. Calculation of volumes ==== ==== 2. Calculation of volumes ====
planning/airtight_construction/airtightness_measurements_in_passive_houses.txt · Last modified: 2023/01/30 11:44 by zbastian