====== Airtightness measurements in Passive Houses ====== | ====== Airtightness measurements in Passive Houses ====== | ||
===== Instructions for carrying out measurements ===== | ===== Instructions for carrying out measurements ===== | ||
- | Airtightness measurements in Passive House buildings are to be carried out uniformly worldwide according to ISO 9972, procedure | + | Airtightness measurements in Passive House buildings are to be carried out uniformly worldwide according to ISO 9972, method |
- | The calculation of the reference volume for passive houses is to be carried out according to the procedure listed below which is not part of the ISO 9972. The resulting volume is to be used for the determination of the n50 value. \\ | + | The calculation of the reference volume for passive houses is to be carried out according to the procedure listed below which is not part of the ISO 9972. The resulting volume is to be used for the determination of the n< |
- | For the calculation and documentation, | + | For the calculation and documentation, |
==== 1. Comparison of designations ==== | ==== 1. Comparison of designations ==== | ||
Line 16: | Line 11: | ||
The superseded standards EN 13829 and the current ISO 9972 use different designations in some places. For a better overview, the most important ones are compared here: | The superseded standards EN 13829 and the current ISO 9972 use different designations in some places. For a better overview, the most important ones are compared here: | ||
- | [{{ :picprivate: | + | [{{ :picopen: |
- | + | ||
- | For measurements in Passive House buildings, the designation in accordance with EN 13829 should continue to be used. | + | |
==== 2. Calculation of volumes ==== | ==== 2. Calculation of volumes ==== | ||
Line 64: | Line 57: | ||
|The only exceptions may be temporarily taping over openings for missing building components, as described above, which affect the airtightness (e.g. missing door sill, missing odour trap in the waste water pipe). Again, an exact record should be kept about such sealing.|**Exception: | |The only exceptions may be temporarily taping over openings for missing building components, as described above, which affect the airtightness (e.g. missing door sill, missing odour trap in the waste water pipe). Again, an exact record should be kept about such sealing.|**Exception: | ||
|**The aim is to obtain realistic results reflecting the building’s airtightness in use, rather than to create an " | |**The aim is to obtain realistic results reflecting the building’s airtightness in use, rather than to create an " | ||
- | |**Negative AND excess pressure measurement**\\ Unlike in the EN 13829 and ISO 9972 standards, both negative pressure AND excess pressure are generally required when measuring the airtightness in Passive Houses. In this way, the reliability of the measurement results is significantly improved, with a minimum of extra effort. Finally, the airtightness parameter of the building is determined as an average value from the negative and excess pressure results.|**Measurement with negative __and__ excess pressure**| | + | |**Negative AND excess pressure measurement**\\ Unlike in the ISO 9972 standards, both negative pressure AND excess pressure are generally required when measuring the airtightness in Passive Houses. In this way, the reliability of the measurement results is significantly improved, with a minimum of extra effort. Finally, the airtightness parameter of the building is determined as an average value from the negative and excess pressure results.|**Measurement with negative __and__ excess pressure**| |
==== 5. Special features of large buildings (qE50-value) ==== | ==== 5. Special features of large buildings (qE50-value) ==== |