 +====== Lengdorf nursery school, Germany ======
 +\\
 +|   **Passive House nursery school\\ Passive House according to PHPP calculations (PHI Darmstadt)**\\ \\ See ID 1308 in the [[http://www.passivhausprojekte.de/projekte.php|Passive House project database]]\\ \\ Specific space heating demand: //**15 kWh/(m²yr)**//\\ Primary energy demand: //**80 kWh/(m²yr)**//\\ Primary Effective Floor Area: //**190 m²**//\\ Effective Floor Area: //**325 m²**//\\ Treated Floor Area: //**290 m²**//\\ Volume: //**1,096 m³**//\\ \\ Construction costs: //**1,890€/m² of Effective Floor Area, incl. VAT**//   |{{ :picopen:lengdorf_nursery_roof.jpg?300 }}|
 +\\
 +\\
 +|{{ :picopen:lengdorf_nursery_cross_section.jpg?500 }}|{{ :picopen:lengdorf_nursery_ground_floor.jpg?480 }}|
 +|//**Lengdorf nursery cross section; AB Vallentin**//|//**Lengdorf nursery ground floor; AB Vallentin**//|\\
 +\\
 +**Construction:**
 +  * //**External wall:**// Plasterboard, OSB, plywood I-beams with 40cm cellulose insulation, MDF, ventilated larch sheathing
 +  * //**Roof:**// OSB, plywood I-beams with 40cm cellulose insulation, MDF (open to diffusion), ventilated corrugated aluminium sheet
 +  * //**Floor slab Basement:**// 12cm perimeter insulation, reinforced concrete floor slab, airtight seal, 18cm insulation
 +  * //**Ground floor:**// Impact sound insulation, floor screed, linoleum
 +  * //**Ventilation, heating, DHW:**// Supply&exhaust air system with cross-flow heat exchanger, pre-heating/cooling via groundwater heat exchanger, pellet boiler, 7 m² flat plate collector, 500 litre thermally layered storage tank\\
 +\\
 +|{{ :picopen:lengdorf_nursery_backyard.jpg?500 }}|{{ :picopen:lengdorf_nursery_front.jpg?371 }}|
 +|//**Backyard of the nursery; AB Vallentin**//|//**Front of the nursery; AB Vallentin**//|\\
 +\\
 +|{{ :picopen:lengdorf_nursery_classroom.jpg?500 }}|{{ :picopen:lengdorf_nursery_hallway.jpg?210 }}|
 +|//**A classroom in the nursery; AB Vallentin**//|//**Hallway; AB Vallentin**//|\\
 +\\
 +--------
 +**Architects:**\\
 +Anna Kragler | Florian Baubin | Dieter Focke,\\
 +[[http://www.vallentin-architektur.de/index.htm|AB Vallentin]]\\
 +84405 Dorfen, Germany\\
 +[[info@vallentin-architektur.de]]\\
 +\\
 +**Building services:**\\
 +[[http://www.itg-landshut.de/|IB ITG]],\\
 +84028 Landshut, Germany\\
 +\\
 +**Statics:**\\
 +IB Jochum,\\
 +82239 Alling, Germany\\
 +\\
 +**Outdoor facilities:**\\
 +[[http://www.vallentin-architektur.de/index.htm|AB Vallentin]],\\
 +84405 Dorfen, Germany
  