efficiency_now:building_envelope:insulating_a_roller-shutter_box
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
efficiency_now:building_envelope:insulating_a_roller-shutter_box [2023/04/26 15:59] – yaling.hsiao@passiv.de | efficiency_now:building_envelope:insulating_a_roller-shutter_box [2023/08/06 21:39] (current) – wfeist | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== Insulating roller shutter boxes : | + | ====== Insulating roller shutter boxes ====== |
+ | {{ : | ||
There just outdoor air inside a roller shutter box - because the gap towards the outside, where the roller shutter exits the box, is permanently open towards the outside. Usually, just a board separates an old roller shutter box from the inside. Heat transmission is particularly high here (2.5 to 4.5 W/(m²K). Making improvements here is relatively easy and also helps a lot. | There just outdoor air inside a roller shutter box - because the gap towards the outside, where the roller shutter exits the box, is permanently open towards the outside. Usually, just a board separates an old roller shutter box from the inside. Heat transmission is particularly high here (2.5 to 4.5 W/(m²K). Making improvements here is relatively easy and also helps a lot. | ||
Line 7: | Line 8: | ||
|<WRAP box 10cm> It is quite easy to cut these panels to size using a sharp knife. A non-compressive low-isocyanate PU adhesive as well as double-sided tape proved suitable for joining these together. </ | |<WRAP box 10cm> It is quite easy to cut these panels to size using a sharp knife. A non-compressive low-isocyanate PU adhesive as well as double-sided tape proved suitable for joining these together. </ | ||
|<WRAP box 10cm> Double-sided adhesive tape applied to the inner cladding panel of the roller shutter box. </ | |<WRAP box 10cm> Double-sided adhesive tape applied to the inner cladding panel of the roller shutter box. </ | ||
- | |<WRAP box 10cm> The cladding panel is now insulated and tape is also applied for protection. The cut-out for the belt can also be seen – a certain amount of leakage will naturally still occur near the opening for the belt, but this is just a single point; and if this is all that remains | + | |<WRAP box 10cm> The cladding panel is now insulated and tape is also applied for protection. The cut-out for the belt can also be seen – a certain amount of leakage will naturally still occur near the opening for the belt, but this is just a single point; and if this is all that remains |
- | |<WRAP box 10cm> What is far more important is the connection joint of the panel, because its length is more than a metre. A matching sealing strip (" | + | |<WRAP box 10cm> What is far more important is the connection joint of the panel, because its length is more than a metre. A matching sealing strip (" |
|<WRAP box 10cm> Because this has a complicated multi-dimensional structure, we calculated this using a numerical heat flow software program, " | |<WRAP box 10cm> Because this has a complicated multi-dimensional structure, we calculated this using a numerical heat flow software program, " | ||
- | Back to overview of [[.:structural_measures|structural measures.]] | + | Back to overview of [[efficiency_now:building_envelope|structural measures.]] |
efficiency_now/building_envelope/insulating_a_roller-shutter_box.1682517561.txt.gz · Last modified: by yaling.hsiao@passiv.de