certification:passive_house_suitable_components [2023/06/29 10:54] srautcertification:passive_house_suitable_components [2023/06/29 14:18] (current) sraut
Line 14: Line 14:
 The specific values are defined so that they really are characteristic of the component behaviour in a built Passive House (e.g. for the balance boundary of ventilation systems in relation to the building envelope). The specific values are defined so that they really are characteristic of the component behaviour in a built Passive House (e.g. for the balance boundary of ventilation systems in relation to the building envelope).
  
-Each of the specific values refers to the relevant product only, any limit conditions regarding the integration into the object as a whole, that have to be complied with, should also be given; for example, the installation situation of the windows. The limit conditions are always chosen with reference to realistic implementation and are not based on artificial laboratory conditions. \\+Each of the specific values refers to the relevant product only, any limit conditions regarding the integration into the object as a whole, that have to be complied with, should also be given; for example, the installation situation of the windows. The limit conditions are always chosen with reference to realistic implementation and are not based on artificial laboratory conditions.
  
 **Certified Passive House Components are listed on the component database [[http://www.componentdatabase.org|www.componentdatabase.org]] ** **Certified Passive House Components are listed on the component database [[http://www.componentdatabase.org|www.componentdatabase.org]] **
Line 27: Line 27:
  
 **[[.:passive_house_categories|The new Passive House Classes]]** **[[.:passive_house_categories|The new Passive House Classes]]**
 +{{vimeo>840814403?medium&h=58479}}
  
 ===== See also ===== ===== See also =====
Line 35: Line 36:
  
 **[[.:addendum_concerning_the_use_of_vacuum_insulation|]]** \\ The introduction of vacuum insulated panels (VIPs) represents an exciting development in the range of available insulation materials for buildings. Passive House Institute (PHI) recommends that this technology be used in a controlled manner, and only where standard, non-vacuum insulation materials cannot be installed or are not economical (under consideration of life cycle costs and shorter service life compared to standard insulation materials). **[[.:addendum_concerning_the_use_of_vacuum_insulation|]]** \\ The introduction of vacuum insulated panels (VIPs) represents an exciting development in the range of available insulation materials for buildings. Passive House Institute (PHI) recommends that this technology be used in a controlled manner, and only where standard, non-vacuum insulation materials cannot be installed or are not economical (under consideration of life cycle costs and shorter service life compared to standard insulation materials).
 +
 +==== Further references ====
 +
 +**[[https://passipedia.org/planning/refurbishment_with_passive_house_components|Refurbishment with Passive House components]]**
 +
 +**[[https://blog.passivehouse-international.org/iphas-qa-with-phi-component-certification-with-edward-lowes/|iPHA’s Q&A with PHI – Component Certification with Edward Lowes ]]**
  
  