Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
certification:passive_house_categories:per [2024/04/18 19:06] – [Introduction] jgrovesmith | certification:passive_house_categories:per [2024/04/18 19:11] (current) – jgrovesmith | ||
---|---|---|---|
Line 4: | Line 4: | ||
This article is an based on the paper "The PER sustainability assessment" | This article is an based on the paper "The PER sustainability assessment" | ||
- | ==== Introduction ==== | + | ===== Introduction |
- | The so-called PER concept (Primary Energy Renewable) were first introduced by Wolfgang Feist at the 18th International Passive House Conference, as future-oriented sustainability assessment criteria ([[basics: | + | The so-called PER concept (Primary Energy Renewable) were first introduced by Wolfgang Feist at the 18th International Passive House Conference, as future-oriented sustainability assessment criteria ([Feist 2014] [[basics: |
This article describes the general methodology used to derive the PER-factors for electricity. | This article describes the general methodology used to derive the PER-factors for electricity. | ||
- | ==== PER factors for electricity: | + | ===== PER factors for electricity: |
- | The methodology used to derive PER factors is based on the ideas that have previously been published in [Feist 2013] and [Feist 2014]. The approach described in these original publications were further developed, applied and analysed internationally, as outlined in this article. With an hourly resolution load profiles of the energy demand are simulated in the context of a future scenario - where the energy is supplied solely from renewable energy sources, including all necessary storage facilities (Figure 1). The individual calculations are based on climate data from various sources, the resulting PER factors describe how much more renewable energy must be supplied in order to cover the final energy consumed at the building, including all losses incurred along the way. For example, a PER-factor of 1.5 indicates that a surplus of 50% renewable primary energy has to be generated in order to be able to meet the final energy demand at the building. | + | The methodology used to derive PER factors is based on the ideas that have previously been published in [Feist 2013] and [Feist 2014] |
- | {{: | + | PER-factor |
The PER factor is determined by the simultaneity of available energy resources and the energy demand, as this dictates how much energy needs to be temporarily stored before it is used. Short-term storage can technically be achieved fairly efficiently, | The PER factor is determined by the simultaneity of available energy resources and the energy demand, as this dictates how much energy needs to be temporarily stored before it is used. Short-term storage can technically be achieved fairly efficiently, | ||
Line 20: | Line 20: | ||
[{{: | [{{: | ||
- | ===== Load profiles – Supply and Consumption | + | ==== Load profiles – Supply and Consumption ==== |
- | ==== Renewable electricity supply | + | === Renewable electricity supply === |
The modelled future energy supply network is based purely on electricity from renewable sources. Three different sources are taken into account: Photovoltaics, | The modelled future energy supply network is based purely on electricity from renewable sources. Three different sources are taken into account: Photovoltaics, | ||
Line 30: | Line 30: | ||
The hourly electricity produced through wind energy is calculated based on a smoothed profile of hourly wind velocities. The same climate data set is used, in order to take account of local climatic correlations between wind and radiation or temperature. However, such localised wind data is rarely representative of the potential of wind energy in the surrounding region. The original wind velocity data is therefore calibrated based on long-term measured averages of the region [SSE] and extrapolated to a hub height of 150 m. The actual power output then depends on the turbine’s power curve, which is modelled with a specific power output of 380 W/m² and 200 W/m² for regions with strong and weak wind, respectively (based on [Mono et.al. 2014]). If the average wind speed at hub height is lower than 4 m/s, a significant development of wind energy in the area is unlikely for economic reasons. The contribution of wind energy to the total mix in the calculations is therefore limited to 0.5 % of the annual yield. Offshore wind energy is not considered at this stage – the calculations are slightly on the safe side in this regard. | The hourly electricity produced through wind energy is calculated based on a smoothed profile of hourly wind velocities. The same climate data set is used, in order to take account of local climatic correlations between wind and radiation or temperature. However, such localised wind data is rarely representative of the potential of wind energy in the surrounding region. The original wind velocity data is therefore calibrated based on long-term measured averages of the region [SSE] and extrapolated to a hub height of 150 m. The actual power output then depends on the turbine’s power curve, which is modelled with a specific power output of 380 W/m² and 200 W/m² for regions with strong and weak wind, respectively (based on [Mono et.al. 2014]). If the average wind speed at hub height is lower than 4 m/s, a significant development of wind energy in the area is unlikely for economic reasons. The contribution of wind energy to the total mix in the calculations is therefore limited to 0.5 % of the annual yield. Offshore wind energy is not considered at this stage – the calculations are slightly on the safe side in this regard. | ||
- | Last but not least, the electricity produced from hydropower is taken into account based on the predicted contribution of this energy source to each country’s future total energy demand. The prediction for future hydropower generation is taken from [intpow 2009]. The future electricity demand is scaled for each country according to current and future population densities, current electricity consumption per capita and the vision of a “2000 Watt Society”. Within Europe it is assumed that countries with a hydropower surplus export part of this electricity. The profile of the hydropower electricity is fairly constant throughout the year and takes into account effects of rain, snow and glacial runoff. | + | Last but not least, the electricity produced from hydropower is taken into account based on the predicted contribution of this energy source to each country’s future total energy demand. The prediction for future hydropower generation is taken from [intpow 2009]. The future electricity demand is scaled for each country according to current and future population densities, current electricity consumption per capita and the vision of a “2000 Watt Society”. Within Europe it is assumed that countries with a hydropower surplus export part of this electricity. The profile of the hydropower electricity is fairly constant throughout the year and takes into account effects of rain, snow and glacial runoff. |
- | ==== Electricity demand at the building | + | |
+ | === Electricity demand at the building === | ||
At the receiving end we differentiate between five different load profiles for different types of energy consumption: | At the receiving end we differentiate between five different load profiles for different types of energy consumption: | ||
Line 43: | Line 44: | ||
[{{: | [{{: | ||
+ | \\ | ||
- | ===== Site-specific PER factors | + | ==== Site-specific PER factors ==== |
In order to determine the PER factor, the respective load profiles of electricity production and electricity consumption are each scaled to 100 kWh/a and compared on an hourly basis. Direct electricity consumption is assumed to the extent of supply and demand matching up. If the supply exceeds the demand, any excess electricity is fed into the storage facilities. Accordingly, | In order to determine the PER factor, the respective load profiles of electricity production and electricity consumption are each scaled to 100 kWh/a and compared on an hourly basis. Direct electricity consumption is assumed to the extent of supply and demand matching up. If the supply exceeds the demand, any excess electricity is fed into the storage facilities. Accordingly, | ||
Line 70: | Line 72: | ||
Figure 5 shows example PER factors for selected climates under very different climatic conditions (all with comparatively small hydropower contribution). The results for household electricity and domestic hot water don’t vary much, with typical values around 1.3 – i.e. 30 % more RE electricity needs to be supplied than can actually be used at the building. The factors for heating, cooling and dehumidification are more strongly influenced by the given local climatic conditions. Unfortunately, | Figure 5 shows example PER factors for selected climates under very different climatic conditions (all with comparatively small hydropower contribution). The results for household electricity and domestic hot water don’t vary much, with typical values around 1.3 – i.e. 30 % more RE electricity needs to be supplied than can actually be used at the building. The factors for heating, cooling and dehumidification are more strongly influenced by the given local climatic conditions. Unfortunately, | ||
- | ===== Regional PER factors worldwide | + | ==== Regional PER factors worldwide ==== |
The methodology to derive PER factors, as described in this article, to begin with are only valid for the specific climate data set used. Calculations for the very same location but a different climate data set (e.g. different time period, different source) will lead to slightly different results. Furthermore, | The methodology to derive PER factors, as described in this article, to begin with are only valid for the specific climate data set used. Calculations for the very same location but a different climate data set (e.g. different time period, different source) will lead to slightly different results. Furthermore, | ||
Line 89: | Line 91: | ||
---- | ---- | ||
- | ==== Literature ==== | + | ===== Literature |
[Feist 2013] Feist, | [Feist 2013] Feist, |
certification/passive_house_categories/per.1713459977.txt.gz · Last modified: 2024/04/18 19:06 by jgrovesmith