certification:passive_house_categories:classic-plus-premium [2015/03/18 16:58] – [Office complex for the Erdinger Moos wastewater association, architects: Architekturwerkstatt Vallentin] bwuensch | certification:passive_house_categories:classic-plus-premium [2015/03/18 17:00] – [Single-family Passive House home in Gerstetten, architect: Werner Friedl] bwuensch | ||
---|---|---|---|
Line 48: | Line 48: | ||
If a small solar thermal array for hot water supply with six square meters of collector area is added, PER demand drops to 47 kWh/ | If a small solar thermal array for hot water supply with six square meters of collector area is added, PER demand drops to 47 kWh/ | ||
- | [{{: | + | [{{: |
==== Passive House Plus with a solar thermal array and heat recovery from shower water ==== | ==== Passive House Plus with a solar thermal array and heat recovery from shower water ==== | ||
Line 67: | Line 67: | ||
In the basic variant (variant 1), | In the basic variant (variant 1), | ||
- | [{{: | + | [{{: |
==== Central hot water supply systems not a good option when little hot tap water is used ==== | ==== Central hot water supply systems not a good option when little hot tap water is used ==== | ||
Line 83: | Line 83: | ||
===== Office complex for the Erdinger Moos wastewater association, | ===== Office complex for the Erdinger Moos wastewater association, | ||
- | A cogeneration unit next to the building produces electricity and heat with gas from the water purification process (Figure 4). The heat is exported to a district heat network for use in space heating and hot water. The cogeneration share of heat is estimated at 94 percent. The lines are very short, so losses are low. The biogas from purification has an PER factor of 1.1, but only within the biomass budget of 20 kWh/ | + | A cogeneration unit next to the building produces electricity and heat with gas from the water purification process (Figure 4). The heat is exported to a district heat network for use in space heating and hot water. The cogeneration share of heat is estimated at 94 percent. The lines are very short, so losses are low. The biogas from purification has an PER factor of 1.1, but only within the biomass budget of 20 kWh/ |
[{{: | [{{: |