certification:enerphit [2015/06/22 09:57] cwebercertification:enerphit [2022/03/08 19:12] wfeist
Line 3: Line 3:
 It is not always possible to achieve the Passive House Standard (new constructions) for [[planning:refurbishment_with_passive_house_components:passive_house_refurbishment_-_introduction|refurbishments of existing buildings]], even with adequate funds. For this reason, the PHI has developed the “EnerPHit – Quality-Approved Energy Retrofit with Passive House Components” Certificate. It is not always possible to achieve the Passive House Standard (new constructions) for [[planning:refurbishment_with_passive_house_components:passive_house_refurbishment_-_introduction|refurbishments of existing buildings]], even with adequate funds. For this reason, the PHI has developed the “EnerPHit – Quality-Approved Energy Retrofit with Passive House Components” Certificate.
  
-Significant energy savings of between 75 and 90 % can be achieved even in existing buildings, for which the following measures have proved to be particularly effective:+Significant energy savings of between 75 and 90 % can be achieved even in existing buildings, for which the following measures have proved to be particularly effective [Bastian 2022]:
  
     * improved thermal insulation (based on the principle: if it has to be done, do it right)     * improved thermal insulation (based on the principle: if it has to be done, do it right)
-    * [[planning:refurbishment_with_passive_house_components:thermal_envelope:minimising_thermal_bridges|reduction of thermal bridges]] +    * [[planning:refurbishment_with_passive_house_components:thermal_envelope:minimising_thermal_bridges|reduction of thermal bridges]]  {{:picopen:members_only.png?20|}} 
-    * considerably [[planning:refurbishment_with_passive_house_components:thermal_envelope:airtightness|improved airtightness]]+    * considerably [[planning:refurbishment_with_passive_house_components:thermal_envelope:airtightness|improved airtightness]]  {{:picopen:members_only.png?20|}}
     * use of high quality [[planning:thermal_protection:windows|windows]] (there is no reason why Passive-House-suitable windows should not be used whenever the opportunity arises)     * use of high quality [[planning:thermal_protection:windows|windows]] (there is no reason why Passive-House-suitable windows should not be used whenever the opportunity arises)
     * [[planning:building_services:ventilation:basics:types_of_ventilation#The convenient solution: supply and exhaust air systems with heat recovery|ventilation with highly efficient heat recovery]] (again, Passive-House-suitable systems are very recommendable)     * [[planning:building_services:ventilation:basics:types_of_ventilation#The convenient solution: supply and exhaust air systems with heat recovery|ventilation with highly efficient heat recovery]] (again, Passive-House-suitable systems are very recommendable)
Line 18: Line 18:
  
 **[[http://www.passiv.de/en/03_certification/02_certification_buildings/04_enerphit/04_enerphit.htm |"EnerPHit" - PHI-Certificate for Refurbishment of existing buildings]]\\ \\ **[[http://www.passiv.de/en/03_certification/02_certification_buildings/04_enerphit/04_enerphit.htm |"EnerPHit" - PHI-Certificate for Refurbishment of existing buildings]]\\ \\
-[[http://passiv.de/downloads/03_certification_criteria_enerphit_en.pdf|Certification Criteria for Energy Retrofits with Passive House Components]] \\ \\+[[http://www.passiv.de/downloads/03_building_criteria_en.pdf|Certification Criteria for the Passive House, EnerPHit and PHI Low Energy Building Standard]] \\ \\
 [[certification:certified_passive_houses:certification_criteria in other languages|Passive House and EnerPHit certification criteria in other languages]]** [[certification:certified_passive_houses:certification_criteria in other languages|Passive House and EnerPHit certification criteria in other languages]]**
 \\ \\ \\ \\
  
 ====== See also ====== ====== See also ======
-[[basics:affordability:investing_in_energy_efficiency:economic_feasibility_of_passive_house_retrofits:factors_that_influence_the_energy_balance_and_affordability_of_non-residential_enerphit_projects|Factors that influence the energy balance and affordability of non-residential EnerPHit projects]]+[[basics:affordability:investing_in_energy_efficiency:economic_feasibility_of_passive_house_retrofits:factors_that_influence_the_energy_balance_and_affordability_of_non-residential_enerphit_projects|Factors that influence the energy balance and affordability of non-residential EnerPHit projects]]  {{:picopen:members_only.png?20|}}
  
-[[certification:enerphit:nternational_enerphit_certification_criteria_for_energy_retrofit_with_passive_house_components]]+[[certification:enerphit:nternational_enerphit_certification_criteria_for_energy_retrofit_with_passive_house_components]]  {{:picopen:members_only.png?20|}}
  
-Certification criteria for the Passive House categories ClassicPlus and Premium+ 
-{{:picopen:phi_building_criteria_draft.pdf|}}+[[http://www.passiv.de/downloads/03_building_criteria_en.pdf|Certification criteria for Passive House, EnerPHit and PHI Low Energy Building]] 
 + 
 + 
 +{{ :picopen:microsoft_word_-_06_fachinfo_schrittweise_modernisierung_sth.pdf | Step-by-step retrofit to achieve EnerPHit-Standard, the example of a single-family home}} 
 + 
 +{{ :picopen:microsoft_word_-_07_window_step_by_step_retrofit_kk.pdf |Windows in step-by-step retrofits - windows first, then insulation }} 
 + 
 +=====Literature===== 
 +[Bastian 2022] Bastian, Z. et al:[[https://rdcu.be/cFgCo|Retrofit with Passive House Components]]; Energy Efficiency, 2022
  
certification/enerphit.txt · Last modified: 2023/10/19 12:36 by yaling.hsiao@passiv.de