Line 4: | Line 4: | ||
* By improving thermal insulation (regardless of the external building component to which it is applied) the heat flow from the inside to the outside is reduced. | * By improving thermal insulation (regardless of the external building component to which it is applied) the heat flow from the inside to the outside is reduced. | ||
+ | |||
* Therefore the heat flow from the building’s interior to the internal surface of this external building component is also reduced. The heat flow overcomes the so-called thermal resistance of the surface (radiation and convection). | * Therefore the heat flow from the building’s interior to the internal surface of this external building component is also reduced. The heat flow overcomes the so-called thermal resistance of the surface (radiation and convection). | ||
+ | |||
* The smaller heat flow results in a smaller temperature loss at this surface, in other words: //the temperature difference between the inside (the surfaces in the room and the indoor air) and the interior surface of the component with improved insulation decreases.// | * The smaller heat flow results in a smaller temperature loss at this surface, in other words: //the temperature difference between the inside (the surfaces in the room and the indoor air) and the interior surface of the component with improved insulation decreases.// | ||
\\ | \\ | ||
Line 24: | Line 26: | ||
\\ | \\ | ||
* The indoor air temperature stratification between the head and ankles of a seated person is less than 2 °C - but only if the ** effective average U-value of the external building component is less than 0.85 W/(m²K)**. See. the illustration on the [[basics: | * The indoor air temperature stratification between the head and ankles of a seated person is less than 2 °C - but only if the ** effective average U-value of the external building component is less than 0.85 W/(m²K)**. See. the illustration on the [[basics: | ||
+ | |||
* The perceived temperatures at various locations in the room differ by less than 0.8 °C.\\ | * The perceived temperatures at various locations in the room differ by less than 0.8 °C.\\ | ||
\\ | \\ |