Line 4: Line 4:
  
   * By improving thermal insulation (regardless of the external building component to which it is applied) the heat flow from the inside to the outside is reduced.   * By improving thermal insulation (regardless of the external building component to which it is applied) the heat flow from the inside to the outside is reduced.
 +
   * Therefore the heat flow from the building’s interior to the internal surface of this external building component is also reduced. The heat flow overcomes the so-called thermal resistance of the surface (radiation and convection).   * Therefore the heat flow from the building’s interior to the internal surface of this external building component is also reduced. The heat flow overcomes the so-called thermal resistance of the surface (radiation and convection).
 +
   * The smaller heat flow results in a smaller temperature loss at this surface, in other words: //the temperature difference between the inside (the surfaces in the room and the indoor air) and the interior surface of the component with improved insulation decreases.//\\   * The smaller heat flow results in a smaller temperature loss at this surface, in other words: //the temperature difference between the inside (the surfaces in the room and the indoor air) and the interior surface of the component with improved insulation decreases.//\\
 \\ \\
Line 24: Line 26:
 \\ \\
     * The indoor air temperature stratification between the head and ankles of a seated person is less than 2 °C - but only if the ** effective average U-value of the external building component is less than 0.85 W/(m²K)**. See. the illustration on the [[basics:building_physics_-_basics:thermal_comfort:Thermal comfort parameters]] page.     * The indoor air temperature stratification between the head and ankles of a seated person is less than 2 °C - but only if the ** effective average U-value of the external building component is less than 0.85 W/(m²K)**. See. the illustration on the [[basics:building_physics_-_basics:thermal_comfort:Thermal comfort parameters]] page.
 +
     * The perceived temperatures at various locations in the room differ by less than 0.8 °C.\\     * The perceived temperatures at various locations in the room differ by less than 0.8 °C.\\
 \\ \\