basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples:iwfs

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples:iwfs [2019/02/21 10:23] cblagojevicbasics:building_physics_-_basics:thermal_bridges:tbcalculation:examples:iwfs [2021/06/21 09:19] (current) – [Interior walls on floor slabs] nsukhija
Line 5: Line 5:
 [{{ :picopen:innenwand_auf_bodenplatte_abb_1.png?600 |Figure 1: Thermal bridge dependent on the distance from the floor slab edge}}] [{{ :picopen:innenwand_auf_bodenplatte_abb_1.png?600 |Figure 1: Thermal bridge dependent on the distance from the floor slab edge}}]
  
-In the case of a specific building the position of the interior wall is known. The Ψ-value can then be calculated based on the same method as in the [[basics:building_physics_-_basics:heat_transferwhat_defines_thermal_bridge_free_design:thermal_bridge_calculation:Examples:EWFS|section on  "Exterior wall on floor slab"]]. For this, first a conductance without taking the interior wall into account is determined and then the conductance with the interior wall taken into account at the corresponding point. However, this requires a three-dimensional calculation which will be too time-consuming in most cases.+In the case of a specific building the position of the interior wall is known. The Ψ-value can then be calculated based on the same method as in the [[basics:building_physics_-_basics:thermal_bridges:tbcalculation:examples:ewfs|section on  "Exterior wall on floor slab"]]. For this, first a conductance without taking the interior wall into account is determined and then the conductance with the interior wall taken into account at the corresponding point. However, this requires a three-dimensional calculation which will be too time-consuming in most cases.
     
 As a two-dimensional approximation, which is also used in the context of certification for a construction system, it is recommended that the ground is taken into account and the distance of the interior wall from the floor slab edge assumed to be 1.5 metres. This procedure is demonstrated below using an example. As a two-dimensional approximation, which is also used in the context of certification for a construction system, it is recommended that the ground is taken into account and the distance of the interior wall from the floor slab edge assumed to be 1.5 metres. This procedure is demonstrated below using an example.
basics/building_physics_-_basics/thermal_bridges/tbcalculation/examples/iwfs.1550741017.txt.gz · Last modified: 2019/02/21 10:23 by cblagojevic