User Tools

Site Tools


affiliate_literature:ventilation

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
affiliate_literature:ventilation [2024/11/12 14:33] – [Heating systems] yaling.hsiao@passiv.deaffiliate_literature:ventilation [2025/01/13 10:58] (current) – [Ventilation] yaling.hsiao@passiv.de
Line 5: Line 5:
  
 ^ ^Publication^Year^Organisation| ^ ^Publication^Year^Organisation|
-|[[https://www.passivhaustrust.org.uk/UserFiles/File/research papers/MVHR/2020.04.27-The Case for MVHR-v7 new cover.pdf|{{https://passipedia.org//lib/plugins/ckgedit/fckeditor/userfiles/image/picopen/4mvhr.jpg?150|4mvhr.jpg}}]]|**[[https://www.passivhaustrust.org.uk/UserFiles/File/research papers/MVHR/2020.04.27-The Case for MVHR-v7 new cover.pdf|Research Report - The case for MVHR]]**  \\  \\ The paper discusses Mechanical Ventilation and Heat Recovery (MVHR) systems in UK homes, which extract warm but potentially stale air from bathrooms, kitchens, and utility rooms. They transfer the heat to fresh outdoor air through a heat exchanger. Despite being beneficial in various domestic situations, MVHR systems are relatively niche in the UK, with trickle ventilation and single-room extract fans being more commonly used. The paper challenges this convention and advocates for wider adoption of MVHR systems in both new-build and retrofit projects.|2020|**[[https://www.passivhaustrust.org.uk/|Passivhaus Trust (PHT), UK]]** | +|[[https://www.passivhaustrust.org.uk/UserFiles/File/Technical%20Papers/MVHR%20Maintenance%20v1%2020241211.pdf|{{:picopen:ventilation_trust.png?140|}}]]|**[[https://www.passivhaustrust.org.uk/UserFiles/File/Technical%20Papers/MVHR%20Maintenance%20v1%2020241211.pdf|MVHR Maintenance: Good Practice Guide]]**  \\  \\ This document provides comprehensive guidance on the maintenance and management of individual Mechanical Ventilation with Heat Recovery (MVHR) units in multi-residential developments. It is intended to serve as a practical resource for clients, maintenance teams, and service personnel. With detailed instructions on service intervals, troubleshooting, and best practices, this guide ensures that MVHR systems are maintained efficiently, promoting energy savings, optimal performance, and good indoor air quality.|2024|**[[https://www.passivhaustrust.org.uk/|Passivhaus Trust (PHT), UK]]** | 
-|[[https://www.passivhaustrust.org.uk/UserFiles/File/Technical Papers/2018 MVHR Good Practice Guide rev 1.2(1).pdf|{{https://passipedia.org//lib/plugins/ckgedit/fckeditor/userfiles/image/picopen/5mvhr1.jpg?150|5mvhr1.jpg}}]]|**[[https://www.passivhaustrust.org.uk/UserFiles/File/Technical Papers/2018 MVHR Good Practice Guide rev 1.2(1).pdf|Technical Guidance - Good practice guide to MVHR for single dwellings]]** \\  \\ Passivhaus guidelines lack need explicit requirements for MVHR system specification, leading to consiconsistently disputes. The document provides specific design guidance for MVHR systems in single dwellings, complementing the ventilation protocol worksheet. Qualified and experienced parties, including Passivhaus consultants and ventilation designers, are recommended for successful implementation. This guidance serves as an addendum to the 'How to build a Passivhaus: Rules of thumb' document, offering valuable design insights not found elsewhere.|2018|**[[https://www.passivhaustrust.org.uk/|Passivhaus Trust (PHT), UK]]** |+|[[https://www.passivhaustrust.org.uk/UserFiles/File/research papers/MVHR/2020.04.27-The Case for MVHR-v7 new cover.pdf|{{https://passipedia.org//lib/plugins/ckgedit/fckeditor/userfiles/image/picopen/4mvhr.jpg?nolink&150|4mvhr.jpg}}]]|**[[https://www.passivhaustrust.org.uk/UserFiles/File/research papers/MVHR/2020.04.27-The Case for MVHR-v7 new cover.pdf|Research Report - The case for MVHR]]**  \\  \\ The paper discusses Mechanical Ventilation and Heat Recovery (MVHR) systems in UK homes, which extract warm but potentially stale air from bathrooms, kitchens, and utility rooms. They transfer the heat to fresh outdoor air through a heat exchanger. Despite being beneficial in various domestic situations, MVHR systems are relatively niche in the UK, with trickle ventilation and single-room extract fans being more commonly used. The paper challenges this convention and advocates for wider adoption of MVHR systems in both new-build and retrofit projects.|2020|**[[https://www.passivhaustrust.org.uk/|Passivhaus Trust (PHT), UK]]** | 
 +|[[https://www.passivhaustrust.org.uk/UserFiles/File/Technical Papers/2018 MVHR Good Practice Guide rev 1.2(1).pdf|{{https://passipedia.org//lib/plugins/ckgedit/fckeditor/userfiles/image/picopen/5mvhr1.jpg?nolink&150|5mvhr1.jpg}}]]|**[[https://www.passivhaustrust.org.uk/UserFiles/File/Technical Papers/2018 MVHR Good Practice Guide rev 1.2(1).pdf|Technical Guidance - Good practice guide to MVHR for single dwellings]]** \\  \\ Passivhaus guidelines lack need explicit requirements for MVHR system specification, leading to consiconsistently disputes. The document provides specific design guidance for MVHR systems in single dwellings, complementing the ventilation protocol worksheet. Qualified and experienced parties, including Passivhaus consultants and ventilation designers, are recommended for successful implementation. This guidance serves as an addendum to the 'How to build a Passivhaus: Rules of thumb' document, offering valuable design insights not found elsewhere.|2018|**[[https://www.passivhaustrust.org.uk/|Passivhaus Trust (PHT), UK]]** | 
  
-\\ 
 ===== Heating systems ===== ===== Heating systems =====
  
affiliate_literature/ventilation.1731418387.txt.gz · Last modified: by yaling.hsiao@passiv.de